English (GB)
8
4.2 Disassembling the plug
Fig. 10
Starting up the pump
4.3 Electrical installation, ALPHA SOLAR
Fig. 11
Control box connections
4.4 Power supply connection, ALPHA SOLAR
Connect the pump to the power supply with the TE Superseal
power plug.
4.5 Control signal connection, ALPHA SOLAR
If you do not need the signal connection, cover it with a blanking
plug. See fig.
.
You can control the pump with a low-voltage PWM (pulse-width
modulation) signal.
The PWM signal is a method for generating an analog signal
using a digital source.
The control signal connection has three conductors: signal input,
signal output and signal reference. Connect the cable to the
control box with a TE Mini Superseal plug. The signal cable can
be supplied with the pump as an accessory.
Step Action
Illustration
1
Loosen the cable
gland and remove
it from the plug.
T
M
05
55
45
38
12
2
Pull off the plug
cover while
pressing on both
sides.
T
M
05
55
46
38
12
3
Add the conductor
guide plate to
loosen all three
cable conductors
at the same time.
If the guide plate
is missing, then
loosen the cable
conductors one by
one by pressing a
screwdriver gently
into the terminal
clip.
TM
05
55
47
38
12
4
The plug has now
been removed
from the power
supply plug.
TM
05 554
8 381
2
T
M
05
30
58
09
1
2
0
1
1 x 230 V ± 10 %
∽
50/60 Hz
T
M
06
58
19
02
16
DANGER
Electric shock
Death or serious personal injury
- Connect the pump to earth.
Connect the pump to an external mains switch with
a minimum contact gap of 3 mm in all poles.
PWM =
Power =