6. Servicing the product

6.1 Service parts

7. Technical data

8. Disposing of the product

This product or parts of it must be disposed of in 
an environmentally sound way:

1. Use the public or private waste collection 

service.

2. If this is not possible, contact the nearest 

Grundfos company or service workshop.

Subject to alterations.

Part

Description

Part number

5 A fuse

Kit, UPZC pump fuse, 5-pack

98996468

250 mA fuse

Kit, UPZC transformer fuse, pump board 250 mA, 5-pack

98996472

500 mA fuse

Kit, UPZC transformer fuse, pump board 500 mA, 5-pack

98996473

Three-zone pump

Four-zone pump

Six-zone pump

Model number

UPZCP-3

UPZCP-4

UPZCP-6

Part number

98863563

98863565

98863566

Input power 60 Hz

120 VAC 

Transformer voltage

24 VAC, 40 VA, Class 2

Thermostat output [A]

0.375

0.5

0.75

Maximum single phase motor rating,
per zone [A]

5

Maximum combined load rating:
output @ 120 VAC [A]

20

Temperature range (storage) [°F (°C)]

50-100 (10-38)

Temperature range
(maximum operation) [°F (°C)]

0-100 (-18 - +38)

Maximum operating humidity range
[%] RH

90

Number of knockouts

12

Size of knockouts [in. (mm)]

0.875 (22)

Dimensions, W x H x D [in. (mm)]

8.15 x 10.67 x 2.72 (208 x 272 x 70)

Approvals

CSA 22.2 No. 24/UL Standard 873

Relay type

Sealed

Cover panel

ABS - fire rated

Base material

Galvanized steel

Terminal block (side mounted)

PA66

Front display lights

LED

Содержание 98863563

Страница 1: ...GRUNDFOS INSTRUCTIONS UPZCP 3 4 6 Multi zone pump control Installation and operating instructions ...

Страница 2: ...rdance with Grundfos printed installation and operating instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact Grundfos or...

Страница 3: ...es you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction 1 3 Symbols used in this document 2 Receiving the product 2 1 Inspecting the product Examine the components carefully to make sure no damage has occurred to the product during shipment 3 Installing the product 3 1 Mechanical installation 3 1 1 Installing the base Attach the base firmly to t...

Страница 4: ... Use approved UL conduit fittings You find additional wiring schematics specs and troubleshooting help online at www grundfos us controls Caution CAUTION Class 2 wiring must be segregated from the wiring of Class 1 circuits When Class 2 wiring is routed with Class 1 wiring the Class 2 wiring insulation must be rated for the minimum voltage of the Class 1 wiring Segregation is not required if all c...

Страница 5: ...at from the boiler Pump Exercise ON The pumps will operate for 30 seconds every 72 hours or every 14 days Primary pump ON During the PRIORITY demand select whether the PRIMARY PUMP is ON or OFF TM06 5605 5015 L N L N ZC ZR L N C B A X X X X R W C R W C R W C R W C R W C R W C L N L N L N L N L N L N L N L N OFF OFF Master SW1 Post Purge ON Priority 30 min Slave Priority ON Pump Exercise ON 60 minu...

Страница 6: ...e MASTER board to activate any boiler or secondary pumps and close the contacts XX MAIN You can connect the pump and valve boards When the SLAVE board calls for heat the secondary pump will be powered If a boiler pump and secondary pump are to be used connect them to the same terminals You can use the low voltage wire to connect ABC terminals Connect the 120 VAC power supply to each board TM06 560...

Страница 7: ...D is lit when there is a call for heat Caution CAUTION Disconnect the power supply before changing any DIP switch settings TM06 5585 0516 Master Slave Allows expansion to additional Grundfos UPZC units Priority ON Zone 1 operates as priority and the other zones are switched off for a selectable 30 or 60 minute timeout Post purge ON The boiler pump will continue to run for two minutes after priorit...

Страница 8: ...ed to the boiler When the contacts close the boiler starts and will come up to a preset temperature for hydronic heating DHW terminal The two terminals labeled PRIORITY XX are wired to the boiler When the contacts close the boiler starts and will come up to a preset temperature for domestic hot water heating ZR and ZC terminals Available on the pump controllers only These terminals are connected b...

Страница 9: ...96473 Three zone pump Four zone pump Six zone pump Model number UPZCP 3 UPZCP 4 UPZCP 6 Part number 98863563 98863565 98863566 Input power 60 Hz 120 VAC Transformer voltage 24 VAC 40 VA Class 2 Thermostat output A 0 375 0 5 0 75 Maximum single phase motor rating per zone A 5 Maximum combined load rating output 120 VAC A 20 Temperature range storage F C 50 100 10 38 Temperature range maximum operat...

Страница 10: ...10 ...

Страница 11: ...3 227 3500 www grundfos us Grundfos Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Fax 1 905 829 9512 www grundfos ca Grundfos México Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto C P 66600 Apodaca N L Mexico Phone 011 52 81 8144 4000 Fax 011 52 81 8144 4010 www grundfos mx ...

Страница 12: ...73387 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Отзывы: