1.2 Rinsing out
preserving agent
Note:
For more detailed information on the handling of the control unit,
refer to chapter F.
Via code 113, (refer to Table E-1: Extract from…), parameter ECL
release the system: To do this, open parameters with the button,
use the button to set ECL: 1 and confirm with the button
Via code 113, (refer to Table E-1: Extract from…), parameter EnL: 1,
open both solenoid valves ("DEAERATE") and rinse preserving
agent out system for 30 minute by opening parameters with
the button, use the button to set EnL: 1 and confirm with
the button
Terminate the "DEAERATE" program step: Open parameter with
button, set EnL:0 with button and confirm with button
Exit the "EnL" program by pressing the and keys at the
same time