6
COMPLETE TROUBLESHOOTING GUIDE
Day & Night Thermostat
TP1
1 – Before you start
***IMPORTANT: READ AND FOLLOW THESE INSTRUCTIONS BEFORE
STARTING THE TEST.
•
THE UNIT MUST BE UNPLUGGED
•
DO NOT PLUG A LOAD INTO THE OUTLET UNTIL STEP 6
•
LIGHTING CONDITION: Perform this test in a room with enough light
for the controller to detect a DAY condition. A dark location should
be avoided.
•
TEMPERATURE: Perform this test in a room where ambient
temperature is between 65°F and 85°F (18°C and 30°C).
•
DEFINITIONS: CW = clockwise, CCW = counterclockwise
•
TURN BOTH KNOBS FULLY CW BEFORE GOING TO STEP 1
2 – Test
STEP
HANDLING AND TEST DESCRIPTION
EXPECTED RESULTS
1
•
Plug the unit into the power outlet
•
WITHIN 5 SECONDS
, turn BOTH
KNOBS fully CCW .
Output On
indicator
will turn ON
2
•
Turn UPPER KNOB fully CW.
Output On
indicator
will turn OFF.
3
•
Cover the
Light Sensor
completely
with the palm of your hand or black
electrical tape(a single finger will
NOT cover the sensor
appropriately)
Output On
indicator
will turn ON after 6 to
8 seconds.
5
Sortie
On
Après 10 sec
sortie
On
Sortie
Off
Sortie
Off
Sortie
Off
Après 10 sec
sortie
On
= Étapes
GUIDE DE DÉPANNAGE RAPIDE
Guide de dépannage rapide
Modèle: TP1
Branchez le TP1
Brancher une charge dans la
sortie du TP1*
Sortie
Off
Après 10 sec
sortie
Off
TP1 fonctionnant en
mode
refroidissement
Après 10 sec
sortie
Off
Sortie
On
TP1 fonctionnant en
mode
chauffage
Produit
défectueux
Bouton Jour:
à
Max
Bouton Nuit :
à
Min
Bouton nuit
à
Max
Produit
défectueux
0
Produit
défectueux
Bouton Jour :
à
Min
Bouton Nuit :
à
Max
Bouton nuit
à
Min
Min :
Bouton à
55°F ou moins
Max :
Bouton à
95°F ou plus
*
Vérifiez préalablement que la charge fonctionne correctement.
A
B
C
F
D
E
Masquez la
photocellule
avec la paume
de la main et
attendez
10 sec
Masquez la
photocellule
avec la paume
de la main et
attendez
10 sec
0
Produit
défectueux
Produit