CONFIGURATION
BLINKING CONTROL MODE BAR:
The selected CONTROL MODE is indicated by one of the lower 5 bars of display.
•
Output is OFF (no voltage on output): Control Mode bar is STEADY LIT, not blinking.
•
Output is ON (120V on output): Control Mode bar IS BLINKING.
Exemple 1
DAY Humidity Indicator is blinking.
Display bar “20” is lit (left scale).
DEHUMIDIFY Bar is lit, but not blinking.
Day Humidify Setpoint is 40%.
Exemple 2
NIGHT TEMPERATURE Indicator is blinking.
Display bar “68” AND “72” are lit (right scale).
HEAT Bar is blinking.
Night temperature Setpoint is 75°C .
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
_________
_________
_________
_________
—
—
—
—
—
—
—
—
—
—
—
—
—
—
_________
_________
_________
_________
The bargraph display
shows a HUMIDITY
level of 20%.
The bargraph display
shows a TEMPERA-
TURE level of 70°F
40
30
20
10
76
72
68
64
DAY is detected and the Output is currently
NOT ACTIVATED (120V) because humidity
level is at 20%.
NIGHT is detected and the Output is
ACTIVATED because the temperature
level is only 70°C.
DAY AND NIGHT DETECTION
The light sensor detects a NIGHT condition when it senses darkness for a minimum period of 8 seconds.
The light sensor detects a DAY condition when it senses light for a minimum period of 8 seconds.
ELECTRONIC BALLAST IN THE SURRONDINGS
Electronic ballasts are generating electronic noises (EMI) that are likely to be picked up by the sensor
cable and alter the reading of the temperature and humidity values. The HT2 incorporates built-in
filters that reduce the effect of EMI, however, we recommend:
1- to place the sensor and cable as far as possible of the ballast, the bulb and the cable between them,
2- to connect the controller on a different 120V outlet / circuit than the one used for the ballast.
6