4
INSTALLATION
1. Fill the drum with
Grease leaving empty
space of about 2” from
the top rim. Shake the
drum after it is filled
to remove air pockets.
Place the follower
plate in the grease
drum with the
lift handle facing
upwards. Push the
follower plate down,
until some grease is
forced through the
centre hole on the
plate.
2. Place the drum cover
on the drum. Lift the
pump assembly &
slide the suction tube
through the drum
cover & centre hole in
the follower plate.
3. Push the pump
assembly down till
the bottom of the
pump touches the
base of the drum.
Adjust the drum cover
and tighten it with
the thumb screws
provided along with
the drum cover.
An FRL (Filter-Regulator-Lubricator) unit must be used in the Air supply, before it is connected to the pump. Set the regulator to 6 BAR (90 PSI)
or any required inlet pressure, but never more than 150 PSI (10 BAR) or less than 30 PSI (2 BAR).
4. Tighten the drum cover
with the pump suction
tube with the help of
thumb screws.
5. Use a wrench to tighten
high pressure hose to the
pump outlet.
6. Use a wrench to tighten
the other end of the hose
to Z Swivel of grease
control valve. Tighten the
outlet extension & coupler
to the control valve outlet.
Use thread sealant on all
connections to ensure
leak-proof working.
7. With the air supply turned
off, connect the Air line
into the air inlet on the
pump.
NOTE
Air Line
Z Swivel
Thumb
Screw
Thumb Screws
Extension
& Coupler
Hose
Lift Handle