Growonix EX1000 Скачать руководство пользователя страница 18

CARBON FILTER CARTRIDGE

Materials:

• 

Filter Media: Granular activated carbon

• 

Outer Shell: Polyethylene

• 

End Caps: Polypropylene

• 

Gasket: Buna-N

• 

Inner Wraps/Core: Polypropylene

• 

Temperature Rating: 40 - 125˚F (4.4 - 51.7˚C)

Maximum Dimensions:

• 

EX1000                4 1/2" X 10”

• 

EX1000-T             4 1/2" X 20"

Initial AP (PSI) @ Flow Rate (GPM):

• 

0.90 PSI @ 4 GPM (.06 bar @ 15.1 L/m)

Chlorine, Taste, Odor 

Reduction Capacity Flow

• 

>70,000  gallons  @  4  GPM  (265,000L  @  15.1 

LPM)

MEMBRANE ELEMENT

Operating Limits:

• 

Membrane Type: Thin film 

     composite

• 

Maximum Operating Temperature: 110˚F 

(43˚C)

• 

Minimum Concentrate Flow Rate: 5:1

• 

pH Range,  Continuous Operation: 3-10

• 

pH Range,  Short term cleaning (30 min): 

1-12

• 

Maximum Feed Water Turbidity:

     1 NTU

• 

Maximum Feed Silt Density Index (SDI): 

5 SDI

• 

Chlorine Tolerance: 0 PPM

Features:

• 

High  Flow  (HF)  Ultra  Low  Pressure 

Membrane Material

• 

Tape Over Wrap

• 

Available Wet Tested

• 

Made in the U.S.A

Flow Rate - gpm (Lpm)

Approximate Net Pressure Drop - psi (Bar)

Applied Pressure PSI (BAR)

• 

1000 GPD: 8.0 (5.52)

Maximum Pressure PSI (BAR)

• 

1000 GPD: 400 (27.58)

Permeate Flow rate GPD

• 

1000 GPD: 1000

Nominal Salt Rejection

• 

97%

18

SPECIFICATIONS CHART

Содержание EX1000

Страница 1: ...1 www growonix com toll free 888 406 8521 office 818 510 0264 sales growonix com EX1000 T EX1000 Owners Manual w w w g r o w o n i x c o m EX1000 EX1000 T Built in the U S A...

Страница 2: ...s filtering process ensures that the solute waste water is contained within the pressurized chamber while the pure solvent RO water is allowed to pass freely through the membrane TUNED FOR GROWING IN...

Страница 3: ...rhouse A pair of liquid filled stainless steel pressure gauges informs when it s time to change the pre filters A manual flush valve allows you to clean the membrane purging out pollutants that could...

Страница 4: ...Recovery System Ratio 50 1 1 Nominal Salt Rejection 97 Permeate Flow GPD 1000 Permeate Flow GPH 42 Min Feed Flow GPM 1 39 Max Feed Water TDS 2000 Max Feed Temp F C 100 37 77 Min Feed Temp F C 40 4 44...

Страница 5: ...oduce the full flow rate Low pressure cutoff to safeguard against a loss of incoming water pressure Stainless steel liquid filled 300 psi pressure gauge Manually controlled or automated with our ESOK...

Страница 6: ...anet with the lowest waste ratio KDF85 CATALYTYIC ACTIVATED CARBON FILTER Premium carbon filter using the best catalytic activated carbon with a bed of KDF85 media There s no better carbon filter avai...

Страница 7: ...while pulling the tubing away from the fitting to release it O RING COLLET TUBING PUSH COLLET IN PULL TUBE OUT GROWONIX WATER FILTERS USE QUICK CONNECT FITTINGS THAT ALLOW FOR EASY MAINTENANCE INFORMA...

Страница 8: ...BRANE 8 O RINGS 9 END CAP 10 SS CLAMP RING 11 FLUSH VALVE 12 FLOW RESTRICTOR 13 DRAIN WASTE WATER OUT 14 AUTO SHUTOFF VALVE 15 RO WATER OUT 16 DRAIN SADDLE CLAMP 17 FILTER WRENCH 18 RO AND DRAIN TUBIN...

Страница 9: ...Only insert the tubing halfway into the drain pipe do not bottom out Connect other end of drain tubing to the included drain clamp 9 Built in the U S A Always turn incoming water pressure off before...

Страница 10: ...on initial startup It is recommended to unhook the membrane input side and flush 40 gallons of water through the carbon filter before re connecting to the RO membrane This will ensure no dust gets int...

Страница 11: ...ly extending membrane life Even weekly flushes will improve membrane life and system performance The flush valve is located on the waste line of the RO membrane To flush the membrane simply turn the f...

Страница 12: ...IED PURIFIED WATER GALLONS AT 1 1 RATIO EX1000 17 000 8 500 EX1000 T 34 000 17 000 EX1000 CARBON FILTER RATED AT 17 000 GALS TOTAL CAPACITY OR 8 500 GALS OF FILTERD WATER AT 1 1 RATIO EX1000 T CARBON...

Страница 13: ...the housing closest to the input side of the unit 3 Grease the O rings with food grade silicone grease 4 5 Turn off the incoming water supply Then open the flush valve to relieve system pressure 1 Tig...

Страница 14: ...lement system must be de pressurized To de pressurize the EX1000 turn incoming water supply completely OFF and open the flush valve It is suggested that you replace sediment and carbon pre filters as...

Страница 15: ...ase to the membrane brine seal and both ends of the core tube Insert the membrane element into membrane housing making sure that the brine seal goes in last 5 9 10 6 Brine Seal last Clean the inside o...

Страница 16: ...minutes close the flush valve and begin normal usage Enjoy 11 12 13 15 17 14 Seat the end cap back into the input side of the membrane housing Replace the stainless clamp on the input side of membrane...

Страница 17: ...GPM 01 bar 38 L min FILTER HOUSINGS Materials of Construction Housing Polypropylene Cap Polypropylene Button Assembly Stainless Steel EPDM Polypropylene O Ring Buna N Maximum Dimensions 13 1 2 X 7 1 4...

Страница 18: ...mits Membrane Type Thin film composite Maximum Operating Temperature 110 F 43 C Minimum Concentrate Flow Rate 5 1 pH Range Continuous Operation 3 10 pH Range Short term cleaning 30 min 1 12 Maximum Fe...

Страница 19: ...to you in good faith without guarantee because each application of this product is different and beyond our control THE FOLLOWING STANDARD OPERATING CONDITIONS FOR RESIDENTIAL COMMERCIAL REVERSE OSMOS...

Страница 20: ...EX1000 T EX1000 Owners Manual w w w g r o w o n i x c o m EX1000 EX1000 T Built in the U S A...

Отзывы: