19
15
Alarm control
Alarm on (default)
Alarm off
16
Backlight control
Backlight on (default)
Backlight off
17
Beeps while primary
source is interrupted
Alarm on (default)
Alarm off
19
C.V. charging voltage
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 56.4V, 48.0V~58.4V Settable
20
Floating charging
voltage.
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 54.0V, 48.0V~58.4V Settable
21
Low DC cut-off
voltage.
If self-defined is
selected in program
5, this program can
be set up
48V model: default 42.0V, 40.0V~48.0V Settable
Lithium battery mode:default 20%, 5%~50% settalbe
22
RS485
Communication Address
Default 001,001-255 Settable
23
Battery equalization
If ”Flooded” or “User-Defined” is selected in program this
program can be set up.