background image

3.4 Storage of Inverter

3.5 The advantage of the unit

3.3 Size and weight

More detail about the type label as the chart below:

Model

Height (H)

Width (W)

Depth (D)

Weight

MIN 2500-6000 TL-XA

350mm 13.8inch 375mm 14.8inch 160mm 6.3inch

9.1kg

If you want to storage the inverter in your warehouse, you should choose an appropriate 
location to store the inverter.

Ø

  The unit must be stored in original package , and should be stored in a clean and dry
  place, and be protected from dust and water vapor corrosion.

Ø

  The storage temperature should be always between -25 and +60 . And the storage

     relative humidity can achieve to 100%.

Ø

  If there are a batch of inverters need to be stored, the maximum layers for original

     carton is four.

Ø

  After long term storage, local installer or service department of GROWATT should

     erform a comprehensive test before installation.

Dimensions and weight

10

9

Model Name

MIN 2500 TL-XA

MIN 3000 TL-XA

MIN 3600 TL-XA

DC nominal input 
voltage

400V

DC input voltage 

range

360~500V

360~500V

360~550V

DC Max 

input/output current

17A

AC nominal voltage

230V

AC grid frequency

50/60 Hz

Max. apparent 

power

2500VA

3000VA

3600VA

Max AC output 
current

11.3A

13.6A

16A

Power factor

0.8leading…0.8lagging

Environmental 

Protection Rating

IP 65

Operation Ambient 
temperature

- 25...+60  (-13...+ 140°F)

with derating above 45°C

 113°F

Model Name

MIN

4200 TL-XA

MIN

4600 TL-XA

MIN

5000 TL-XA

MIN

6000 TL-XA

DC nominal input 
voltage

400V

DC input voltage 

range

360~550V

DC Max 

input/output current

17A

AC nominal 
voltage

230VAC

AC grid frequency

50/60 Hz

Max. apparent 
power

4200VA

4600VA

5000VA

6000VA

Max AC output 

current

19A

20.9A

22.7A

27.2A

Power factor

0.8leading…0.8lagging

Environmental 
Protection Rating

IP 65

Operation Ambient 
temperature

- 25...+60  (-13...+ 140°F)

with derating above 45°C

 113°F

375

3

5

0

160

Ø

  Max. efficiency of 98.4%.

Ø

  40% lighter.

Ø

  Storage ready.

Ø

  Compatible with double-glass bifacial modules.

Содержание MIN 2500TL-XA

Страница 1: ...IN 4600TL XA MIN 5000TL XA MIN 6000TL XA GR UM 257 A 00 Download Manual Growatt New Energy Shenzhen Growatt New Energy Co Ltd 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an...

Страница 2: ...on of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in this...

Страница 3: ...nnectors info 14 3 Torque 14 4 Accessories 6 Electrical connection 13 Decommissioning 7 Commissioning 14 Technical Data 7 1 Start the inverter 7 2 General setting 7 3 Advanced setting 7 4 Communicatio...

Страница 4: ...es the assembly installation commissioning and maintenance of the following Growatt Inverter model MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA MIN 4200 TL XA MIN 4600 TL XA MIN 5000 TL XA MIN 6000 TL...

Страница 5: ...r The external wireless communication does not require line of sight between the devices and it is selective purchasing Safety 2 The unit converts the DC current generated by the battery BAT to grid c...

Страница 6: ...of accidents Systems with inverters typically require additional control e g switches disconnects or protective devices e g fusing circuit breakers depending upon the prevailing safety rules DANGER E...

Страница 7: ...off 0 5s on 2S off programming Yellow 1s on and 1s off The type labels provide a unique identification of the inverter The type of product Device specific characteristics Certificates and approvals T...

Страница 8: ...imensions and weight 10 9 Model Name MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA DC nominal input voltage 400V DC input voltage range 360 500V 360 500V 360 550V DC Max input output current 17A AC nom...

Страница 9: ...regulations for the complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no user serviceabl...

Страница 10: ...oids forward and sideways tilt Be sure that the inverter is out of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near television anten...

Страница 11: ...d leave 2 to 4mm exposed Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wa...

Страница 12: ...XA MIN 6000 TL XA The AC wiring step 1 Uninstall the parts of the AC connection plug from the accessory bag 2 Insert the stripped and bared cable through pressure screw seal ring threaded sleeve in s...

Страница 13: ...then pull it out Wire suggestion length Conductor cross section Max cable length MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA 4 mm 12AWG 48m 40m 33m 5 2 mm 10AWG 60m 50m 42m Conductor cross section Ma...

Страница 14: ...erable damage to the inverter Only qualified personnel can perform the wiring work WARNING WARNING 6 3 Connecting the second protective conductor In some installation countries a second protective con...

Страница 15: ...um ion battery pack is not properly connected or the electrical disconnection will cause the equipment to work abnormally or even damage the equipment 6 5 Connecting signal cable This series inverter...

Страница 16: ...ower output levels of an inverter The export limit control function for an inverter is used to control the generation from an inverter to manage the export power level from an electrical installation...

Страница 17: ...RM6 DRM7 DRM8 are available Damage to the inverter due to moisture and dust penetration Make sure the cable gland has been tightened firmly If the cable gland are not mounted properly the inverter can...

Страница 18: ...age the inverter External voltage of PCI PORT don t over 5V WARNING 6 8 1 2 Method of asserting demand response modes RRCR PCI Connector 6 8 2 1 8Pin socket pin assignment Pin Description Connect to R...

Страница 19: ...ther region after 30s When inverter powered on OLED will light automatically Once the BAT power is sufficient OLED displays the following Press the touch key once a second to scroll through the differ...

Страница 20: ...2019 04 18 Double touch Date Setting 20NN 04 18 Double touch Double touch Date Setting 20NN 04 18 Multiple single touch Date Setting 20NN NN 18 Double touch Multiple single touch Date Setting 20NN NN...

Страница 21: ...e touch ExportLImit Rate 000 0 ExportLImit Rate 0N0 0 Double touch Multiple single touch ExportLImit Rate 0N0 0 ExportLImit Rate 0NN 0 Multiple single touch Set OK Double touch Double touch ExportLImi...

Страница 22: ...Disable LoadFirst 00 01 Time1 Enable Multiple single touch Multiple single touch Multiple single touch Double touch Double touch Double touch Double touch Double touch Double touch Single touch Single...

Страница 23: ...5A2 Connect Min ShineBus or third party monitoring equipment 7 BAT B Connect the BAT communi cation RS485B or CANL 4 RS485B2 Connect Min ShineBus or third party monitoring equipment 8 BAT A Connect th...

Страница 24: ...issipation 9 2 Cleaning the Inverter 9 3 Checking the DC Disconnect If the inverter regularly reduces its output power due to high temperature please improve the heat dissipation condition Maybe you n...

Страница 25: ...by system instead of inverter please check the items as instructed below before replacing inverter Error message Description Suggestion Residual I High Error 201 Leakage current too high Restart the...

Страница 26: ...7 The data sampled by the DSP and redundant M3 is not the same 1 Restart inverter 2 I f problem still exist contact Growatt Error 420 GFCI fault 1 Restart inverter 2 I f problem still exist contact Gr...

Страница 27: ...HDi 3 AC grid connection type Single phase L N PE AC overvoltage category Category III Model Specifications MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA MIN 4200 TL XA AC input quantities Nominal AC i...

Страница 28: ...m continuous 17A DC output quantities Nominal DC output voltage 400V DC output voltage range 360 550V DC output current maximum continuous 17A Battery type Cobalt Free Lithium Iron Phosphate LFP AC ou...

Страница 29: ...monitoring Integrated Anti islanding protection Integrated Active Frequency Drift Residual current monitoring unit Integrated General data Dimensions W H D in mm 375 350 160 Weight 9 1 kg Operating te...

Страница 30: ...nfo 14 3 Torque BAT connectors VP D4B CHSM0B VP D4B CHSF0B AC connector VPAC06EP 3S SC 5 EN032 1128 1001 VPAC06EW 3P SC Enclosure lid screws 12kgf cm AC terminal 6kgf cm Signal terminal 4kgf cm M6 sok...

Отзывы: