background image

 

 

 
 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.5kWh Residential Energy Storage Battery Manual   

 

 

Version: 1.1 

Date: 2019-08-07 

 

 

 

 

 

 

 

 

  

Содержание GBLI 6531

Страница 1: ...0 6 5kWh Residential Energy Storage Battery Manual Version 1 1 Date 2019 08 07...

Страница 2: ...ensure that you are familiar with product features functions and safety precautions as provided in this document Warning and caution messages are listed in the document to remind users installers and...

Страница 3: ...n Requirements 10 3 2 Installation Required Tools 11 3 3 installation Procedures 11 3 3 1 Wall Mounted Installation 12 3 3 2 Floor Standing Installation 14 4 Electrical Connection 15 4 1 Preparation 1...

Страница 4: ...le Certification in European Union area Risk of electric shock Explosive gas Battery may leak corrosive electrolyte Battery is heavy enough to cause severe injury Keep battery away from children Do no...

Страница 5: ...wet hands Keep battery away from children and animals A battery can present a risk of electric shock and burns by high short circuited current Battery installation and wire connection must be operate...

Страница 6: ...not put battery upside down or sidelong Store batteries in a place free from direct sunlight and rain Keep batteries at least two meters away from a heat source such as a radiator Avoid contacting wi...

Страница 7: ...s to power off battery During transportation put battery flat do not have battery stand or lean on the floor to avoid possible crash Maintain temperature between 20 to 45 during the transportation Pro...

Страница 8: ...cycle life and less self discharging loss The build in BMS can monitor battery operation status and alarm timely to avoid operation out of limit Two batteries can be parallel connected to expand ener...

Страница 9: ...ion failure happens Forced power off when battery does not connect to mains supply press POWER button for two seconds and battery powers off Activation input 45V 60V via P P terminals battery will be...

Страница 10: ...10 45 Optimal operating temperature 0 30 7 Storage conditions Within 6 month after initial charge temperature 20 45 humidity 5 RH 95 RH 8 Room temperature cycle life 25 C 6000 cycles 60 EOL 9 Cooling...

Страница 11: ...5o 5o is allowed for both installation against wall and floor Additionally the distance between the bottom part of battery and floor should not exceed 500mm Please refer to figures below means accepta...

Страница 12: ...lic plier Insulated gloves Safety goggle Safety shoes 3 3 installation Procedures Pre installation Check Check exterior package before opening package check for damages like holes cracks or other trac...

Страница 13: ...1 PCS Optional Accessories Single battery Parallel connected batteries Fastening M8 expansion screw 2PCS M8 H60 anchor bolt 2PCS Gradienter 1PCS M8 expansion screw 4PCS M8 H60 anchor bolt 4PCS Gradie...

Страница 14: ...ert power cable and network cable into battery terminals Having confirmed fixed installation plug power cables into battery terminals orange positive terminal and black negative terminal Plug CAN netw...

Страница 15: ...ots Move battery away Choose an alloy drill bit with a diameter of 12mm and install it in the drill Drill two holes in the spots that have been confirmed in step 1 Keep the drilling depth as least 60m...

Страница 16: ...screw Step 2 Make power cables 1 Strip cable sheaths for 20 0 5mm with orange positive cable and black negative cable Insert sealing sealing nut and protection cover along the cable as shown 2 Insert...

Страница 17: ...o wires stay aligned and keep consistent between wire color and pin 3 Crimp the RJ45 plug with a wire crimper 4 Connect RJ45 plug with joint sleeve and tighten up sealing sealing nut and joint sleeve...

Страница 18: ...ery bus bar box and wall as shown unit mm Step 2 Insert power cables into battery terminals Make the power cables of both batteries based on Section 4 2 Step 2 Plug one end of positive and negative te...

Страница 19: ...two batteries and CAN network cable only applies to the communication between battery and PCS Ensure two batteries in parallel connection are from the same batch same model and same manufacturer Do no...

Страница 20: ...fore checking battery Measure battery voltage with a multi meter and ensure voltage output under off mode is 0V If any abnormality is detected when powering on immediately power off the battery Procee...

Страница 21: ...normal battery powers on successfully 2 If the ALM light turns red the indication shows a failure The failure shall be fixed before powering on again Power on parallel connected batteries by pressing...

Страница 22: ...communication between batteries works 2 If the ALM light of one battery or both batteries turn red there is a parallel connection failure and should be fixed before powering on again 6 3 Power off Ba...

Страница 23: ...inals For wall mounted battery rotate both latches upward Two persons lift up battery off bracket For floor standing battery unscrew expansion screws with a cross screwdriver rotate latches upward and...

Страница 24: ...cell voltage below the threshold for under voltage protection There is over discharge risk User should stop discharging and arrange recharge Protection against level three charge over voltage Single...

Страница 25: ...and battery Protection against short circuit discharge Protection against prallel connection failure Communication failure between two parallel connected battery Check if RS485 wire between PCCKs and...

Страница 26: ...ailure Current limitation failure ALM light maintains on There is safety risk and user should stop using battery User should contact installer to repair battery T 86 0755 2747 1942 E service ginverter...

Отзывы: