6.3.2 Power on Display

Power on display

After  inverter  restarts,  LCD  background  will  light  automatically.  Growatt  Logo  will 
appear  immediately.  The  background  light  will  last  for  2  seconds.  See  Fig6.3.5  for 
reference.

Fig6.3.5 Power on Growatt Logo

After  displaying  Growatt  Logo  for  2  seconds,  LCD  screen  will  switch  to  the  second 
interface; display the figure of inverter, company name, inverter’s power rating, etc. 
The second interface will last for 3 seconds. See Fig6.3.6 for reference.

Fig 6.3.6 The second power on interface

After 3 seconds, it will switch to the third interface. See Fig6.3.7 for reference.

Fig6.3.7 The third power on interface

Here is explanation of items on Fig6.3.7:

No.: Serial number of this inverter.
Model: model name of this inverter.
Main Ver: firmware version of control board.
Comm Ver: firmware version of communication board.

After  displaying  information  of  the  third  interface  for  3  seconds,  the  background 
light will turn off.

·
·
·
·

LCD Display when backlight off

After  the  power  on  information  is  displayed  automatically  and  the  backlight  turns 
off, the LCD display will switch to the following Interface 1. There are 4 interfaces, 
which can be displayed in turn by single knock.

Interface 1:
state description, for example, in faulty state it will display ERROR and followed with 
faulty  codes,  which  is  convenient  to  compare  with  error  code  list  in  manual.  The 
second  line  displays  inverter’s  states  name;  and  the  third  line  displays  energy 
generated  today,  and  the  forth  line  displays  the  total  energy  generated  since 
installation.

 Running state. See Fig 6.3.8 as reference. The first line displays inverter’s 

Fig6.3.8 Interface 1: Running state

Fig6.3.9 Interface 2: Input information

nterface 2: 

This interface displays parameters of PV input, including input voltage, current, and 
power of each MPP tracker.

·

V-pv: Input voltage of MPPT1 and MPPT2

·

I-pv: Input current of MPPT1 and MPPT2

·

P-pv: Input power of MPPT1 and MPPT2

Input information. See Fig6.3.9 for reference.

No: 0000000000

Model:GTGF00XXXX

Main Ver:XXXXXXX

Comm Ver:XXXXXXX

State Fault

           ERROR 101
E_day:00.0
E_ALL:596

State Fault

 V_pv:000/000 V

I_pv:00.0/00.0 A
P_pv:000/000 W

Input Info

Содержание 30000 TL3

Страница 1: ...LTD 1st East 3rd Floor Jiayu Industrial Zone Xibianling Shangwu Village Shiyan Baoan District Shenzhen P R China 86 755 2747 1900 86 755 2749 1460 info ginverter com Www ginverter com T F E W GR UM 0...

Страница 2: ...or fitness for any particular purpose All such warranties are expressly disclaimed Neither Shenzhen Growatt New Energy Technology Co Ltd nor its distributors or dealers shall be liable for any indirec...

Страница 3: ...PPT of the Growatt TL3 6 6 Communication Start up and Shut down the inverter 7 7 1 Start Up the inverter 7 2 Shut down the Inverter Maintenance and Cleaning 8 Trouble shooting 9 10 1 Dismantling the I...

Страница 4: ...o observe these instructions For possible changes in this manual SHENZHEN GROWATT NEW ENERGY TECHNOLOGY CO LTD accepts no responsibilities to inform the users 1 1 3 Storage of the manual 1 1 4 Additio...

Страница 5: ...ains Growatt TL3 series inverters or any other Growatt inverters the system designing software ShineDesign download from site www ginverter com will provide adequate supports AC Abbreviation for Alter...

Страница 6: ...Assembly Warnings absence of any transport or handling damage which could affect insulation integrity or safety clearances failure to do so could result in safety hazards Unauthorized removal of nece...

Страница 7: ...watt TL3 series inverters need install a separate energy meter The energy produced is compensated at a rate depending on the electric power company 2 5 Operation Warnings during operation Although des...

Страница 8: ...of connection for grounding protection Operation after 5 minutes Direct Current DC Alternating Current AC EU waste electrical and electronic equipment WEEE label Product Description 3 3 1 Inverter ove...

Страница 9: ...discover any visible damage to the inverter We will be glad to assist you if required When transporting the inverter the original or equivalent packaging should to be used and the maximum layers for o...

Страница 10: ...RF Ethernet Wi Fi Wide PV voltage range 180V 1000V The maximum efficiency is 98 2 IP65 environmental protection Remote update capability Easy to install Fig 4 1 Item A B C D E F G H I Quantity 1 1 1...

Страница 11: ...after the unit is disconnected from the grid and photovoltaic panels high voltages may still exist inside the PV Inverter Do not remove the casing until at least 5 minutes after disconnecting all pow...

Страница 12: ...verter should be 25 60 The installation location must be freely and safely to get at all times Vertically installation and make sure the connection of inverter must be downwards Never install horizont...

Страница 13: ...he bracket is firmly mounted on the wall then mount the inverter on the bracket Rise up the Growatt TL3 a little higher than the bracket Considering the weight of Growatt TL3 you need to hang on the i...

Страница 14: ...n or snow to extend the inverter service life despite the IP65 protection degree Exposure to the sunlight may cause additional internal heating which will cause power derating Fig 5 7 Fig 5 8 More tha...

Страница 15: ...rrent in the event of a malfunction in the original protective conductor For installation countries falling within the scope of validity of the IEC standard 62109 you must Installthe protective conduc...

Страница 16: ...verter NEVER connect or disconnect the DC connectors under load Improper operation during the wiring process can cause fatal injury to operator or unrecoverable damage to the inverter Only qualified p...

Страница 17: ...000 TL3 33000 TL3 40000 TL3 Max current 35A 38A 38A 5 In order to seal the inverter all unneeded DC inputs must be closed with sealing plugs Cable requirements 30000 TL3 33000 TL3 40000 TL3 Model 2 05...

Страница 18: ...er should not be connected to PE 5 5 Grid Type 5 5 1 Common grid type For TT grid mode the valid value of the Neutral to PE voltage should be less than 30 V Based on the local GRID standards it may se...

Страница 19: ...Whenever the DC voltage is higher than 300Vdc inverter converts power to grid as generated by the PV panels Whenever the DC voltage is lower than 250Vdc the inverter will work in waiting state and at...

Страница 20: ...played can be changed by knock you can also change some inverter parameters by knock Fig 6 3 1 Fig 6 3 2 Note have been preset in factory and you don t need to operate this step any more If you have o...

Страница 21: ...ht off After the power on information is displayed automatically and the backlight turns off the LCD display will switch to the following Interface 1 There are 4 interfaces which can be displayed in t...

Страница 22: ...aximum energy yield of one hour Power curve The daily energy yield curve 6 3 2 3 Connecting messages When inverter started to connect to grid the following message will appear on LCD screen See Fig6 3...

Страница 23: ...rameters setting First level menu It is a little bit different to enter the first level menu note that using thrice knock to enter first level menu instead of double knock Fig 6 3 14 is the interface...

Страница 24: ...ut current for each MPP tracker PV input power for each MPP tracker Inverter output parameters AC output voltage for each phase AC output current for each phase AC output power for each phase Third le...

Страница 25: ...rd level menu interface of working information State information First level menu Second level items Item explanation No xxxxxxxxxx Model xxxxxxxxxx Main Ver xxxxxx Comm Ver xxxxxx Serial number of th...

Страница 26: ...ly if user saves save the choice by double knock and LCD displays Set OK The inverter provides five languages Italian English German Spanish and French The number on Set language interface is sequence...

Страница 27: ...d bar of the graph represents the current unit of time Day h Week day Month M Year Y The top bar of the graph represents the maximum value of the graph values The daily graph is displayed by default Y...

Страница 28: ...ine switch to the text as follow 2 Knock the enclosure lid twice and the text will show the language 3 You can choose the language by tripping the enclosure once the language includes English Deutsh E...

Страница 29: ...once every time until the text line switch to the text as follow 2 Double knock the enclosure lid and switching to external wireless communication 3 Then knock the enclosure three times to confirm it...

Страница 30: ...nd must not be used for billing purposes The inverter s measurement values are required for the operational control and to control the current to be fed into the electricity grid The inverter does not...

Страница 31: ...6 2 Monitor the inverters The inverter provides RS485 interface and RS232 interface to communicate with remote PC or logger User can monitor the inverter state via the following types of communicatio...

Страница 32: ...Through RS232 interface wireless module Data logger PC Through RS232 interface wireless module Data logger Internet Plan B 57 58...

Страница 33: ...through the hole of cable gland and put the cable into the RS485 terminals fix all cables with screwdriver 1 to 1 3 to 3 2 to the shielding layer or no connection The type of cable is recommended as...

Страница 34: ...ing fans failed Ventilation of installation location is poor Choose appropriate installation location before mounting Maintain fans and heatsink every half a year to reduce the power derating caused b...

Страница 35: ...the fans in reverse order 9 1 Error Messages displayed on LCD An error message will be displayed on the LCD screen when a fault occurs The faults consist of system fault and inverter fault You may be...

Страница 36: ...han 1 M If the error message is displayed despite the above checking passed contact Growatt 1 Restart invert 2 If error message still exists contact Growatt 1 Restart inverter 2 If error message still...

Страница 37: ...Error 117 Error 119 Error 121 GFCI fault Control board has not received data from Communication board for 5S Restart inverter if problem still exist contact Growatt Restart inverter if problem still e...

Страница 38: ...1000V 38A 38A 61 6kg 55 dB A Smart cooling IP 65 Transformerless 2000m without derating 0 100 551 740 276 mm 25 C 60 C with derating above45 C 0 5W Growatt 40000TL3 Datasheet H4 MC4 opt Screw termina...

Страница 39: ...Shine Vision receiver Shine Vision emitter Internal fan of Growatt TL3 Outside fan of Growatt TL3 Communication interface Communication interface Communication data logger Communication data logger re...

Страница 40: ...ter type 2 Modules information 3 Communication method 4 Serial number of Inverters 5 Error code of Inverters 6 Display of inverter Shenzhen Growatt New Energy Technology CO LTD 1st East 3rd Floor Jiay...

Отзывы: