Unpacking

Before opening the packing box of UE series inverter, please note that whether there 
are any visible external damages.

Once open the packing box, please check the delivery for completeness and for any 
visible external damages of the inverter. If there are anything damaged or missing, 
please contact your dealer. Complete delivery should contain as follows.

Item 

Number

Description

Information

Though the packaging box of TL3-S is durable, please treat the 
packing box gently and avoid dispose the packing box.

11

  12

A

1

Inverter

B

Quick installation guide

C

3

Cable gland for AC connection

D

4

M4 cross recessed countersunk head screws

E

1

Rs485 terminals

F

4

Expansion bolt

G

5

Cord End Terminal

H

I

*

1

2/3

RJ 45 PLUG  Only for Australia

(

)

PV connectors   

--

1

User manual (not show in the picture)

Installation 

5  

 

 

5.1 Safety instruction

Danger to life due to fire or explosion 

Despite careful construction, electrical devices can cause fires.

Do not install the inverter on easily flammable materials and where 
flammable materials are stored.

Risk of burns due to hot enclosure parts

Mount the inverter in such a way that it cannot be touched  
inadvertently.

Possible damage to health as a result of the effects of radiation!

In special cases, there may still be interference for the specified application 
area despite maintaining standardized emission limit values (e.g. when 
sensitive equipment is located at the setup location or when the setup 
location is near radio or television receivers).In this case, the operator is 
obliged to take proper action to rectify the situation.

Never install the inverter near the sensitive equipment

e.g. Radios, 

telephone, television, etc

Do not stay closer than 20 cm to the inverter for any length of time unless it 
is absolutely necessary.

We assumes no responsibility for compliance to EMC regulations for the  
complete system.

All electrical installations shall be done in accordance with the local and 
national electrical codes. Do not remove the casing. Inverter contains no 
user serviceable parts. Refer servicing to qualified service personnel. All 
wiring and electrical installation should be conducted by a qualified 
service personnel.

Carefully remove the unit from its packaging and inspect for external 
damage. If you find any imperfections, please contact your local dealer.
Be sure that the inverters connect to the ground in order to protect 
property and personal safety.
The inverter must only be operated with PV generator. Do not connect 
any other source to it.

Both AC and DC voltage sources are terminated inside the PV Inverter. 
Please disconnect these circuits before servicing.
This unit is designed to feed power to the public power grid (utility) only. 
Do not connect this unit to an AC source or generator. Connecting 
Inverter to external devices could result in serious damage to your 
equipment.

* 7000-11000TL3-S & 12000TL3 2 Pairs
* 12000TL3-S & 15000TL3-S 3 Pairs

Содержание 10000TL3-S

Страница 1: ...L3 S Growatt 5000TL3 S Growatt 4000TL3 S Growatt 3000TL3 S Growatt 11000TL3 S Growatt 13000TL3 S Growatt 15000TL3 S Installation Operation Manual Shenzhen Growatt New Energy Technology CO LTD No 28 Gu...

Страница 2: ...3 4 Transportation Unpacking Index 1 2 3 4 2 2 Safety Precautions Installation 5 5 1 Safety instruction 5 2 Selecting the Installation Location 2 3 Assembly Warnings 2 4 Electrical Connection Warning...

Страница 3: ...the Inverter 8 2 Checking the DC Disconnect Trouble shooting 9 10 1 Dismantling the Inverter 10 2 Packing the Inverter Decommissioning 10 10 3 Disposing of the Inverter Specification 11 Certificates...

Страница 4: ...ch if not avoided could result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury NOTICE indicates a situation which if not...

Страница 5: ...r coupling capacity does not exceed 2 2uF During feed in operation a leakage current flows from the cells to earth the size of which depends on the manner in which the PV modules are installed e g foi...

Страница 6: ...AC current generated as follows 5 6 2 2 Safety Precautions The TL3 S series Inverter is designed and tested according to Internalational safety requirements however certain safety precautions must be...

Страница 7: ...ions comply with all corresponding safety symbols and markings present on the unit and in this manual In special cases there may still be interference for the specified application area despite mainta...

Страница 8: ...f there are lots of inverters need to be stored the maximum layers for original carton is four After long term storage local installer or service department of manufacturer should perform a comprehens...

Страница 9: ...it values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged to take proper action to r...

Страница 10: ...c panel is exposed to light it generates a DC voltage When connected to this equipment a photovoltaic panel will charge the DC link capacitors Energy stored in this equipment s DC link capacitors pres...

Страница 11: ...me installation countries a second protective conductor is required to prevent a touch current in the event of a malfunction in the original protective conductor For installation countries falling wit...

Страница 12: ...re to the sunlight may cause additional internal heating which will cause power derating More than one inverter need to be installed the dimensions below should be considered Fig5 6 Fig5 7 Fig 5 8 Rec...

Страница 13: ...grid voltage and frequency Voltage 400Vac Frequency 50Hz 60Hz 3 Phase Open the breaker between the PV inverter and utility Specification of AC breaker Cable requirements 1 The AC side terminals of th...

Страница 14: ...he inverter To reduce the risk of electric shock avoid touching the live components and treat the terminals carefully Information Please use the same brand male and female PV connectors Under any cond...

Страница 15: ...e maximum string currents are varying from different inverter types Model Max current 7000TL3 S 3000 6000TL3 S 8000 9000TL3 S 10000 11000TL3 S 12000TL3 12000 15000TL3 S 11 5A 11 5A 11A 11A 11 5A 11 5A...

Страница 16: ...es The inverter starts up automatically when DC power from the PV panel is sufficient Fault Mode The internal intelligent controller can continuously monitor and adjust the system status If inverter f...

Страница 17: ...afety standard must be selected by the DIP switch The DIP switch is composed of four digit binary number PINS The different combination of the four PINS can represent different inverter s model which...

Страница 18: ...4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 AS4777_Newzealand GT1XXXXXX0 Reserved GT1XXXXXX1 India GT1XXXXXX2 EN50438_Demark GT1XXXXXX3 EN50438_Sweden GT1XXXXXX4 EN50438_Norway G...

Страница 19: ...l 2000 Kwh AC Volt A B C 230V 230V 230V Set Language Set Language English Once Once Once Double Fig6 3 Overall display interface Power on display After inverter restarts the background light will last...

Страница 20: ...Com Address 001 Set Language Set Date Time AC V Control Disable Enable Once Once Once Setting Three Set Language English Double AC V Control Disable Double Double Date 2012 04 05 Time 14 20 38 Settin...

Страница 21: ...ime Date 2013 05 06 Time 14 20 38 Date 2013 05 06 Time 14 20 38 Date 2013 05 06 Time 15 20 38 Date 2013 05 06 Time 15 20 38 Date 2013 05 06 Time 15 21 38 Set OK Double Once Double Once Double Once Dou...

Страница 22: ...ication systems You can update firmware via RS232 or Rs485 The connecting diagram as follow Active power control with a ripple control signal receiver Through RS485 interface RS485 232 RS232 converter...

Страница 23: ...t be more than 32 6 5 3 RS485 cable connection Rs485 cable connection Pin1 TR B Pin2 Shielding layer or no connection Definitions of RS485 PLUG standard as follows Pin1 TR B Pin2 Shielding layer or no...

Страница 24: ...recommended as STP FTP ASTP 4 Plug in two terminals Cover the fix board Information Tighten 4 pcs screws first then tighten cable gland 5 Tighten 4pcs screws and cable gland Note 1 As to the connecti...

Страница 25: ...off the DC switch of the inverter 3 Check the inverter operating status 4 Until the display of LCD goes out the inverter is shut down Once the output power is derating because of too high warming some...

Страница 26: ...acing inverter Error message Description Suggestion Error 124 No AC connection Check AC wiring Check the status of AC breaker PV Isolation Low Insulation problem 1 Check if panel enclosure ground prop...

Страница 27: ...oblem still exist Contact Growatt Warning 109 Warning 108 PV 1 or PV2 Circuit short PV 1 or PV2 boost broken Check the PV panel polarity Restart the inverter If the warning still exist please contact...

Страница 28: ...unit and where applicable any accessories are disposed of in a proper manner 11 Specification 11 1 Specification of TL3 S Model 3000TL3 S 4000TL3 S 6000TL3 S 5000TL3 S Specification Input data Max DC...

Страница 29: ...wer factor at rated power 1 1 1 1 Adjustable displacement power factor THDi Full load THDv 1 0 8leading 0 8laging AC grid connection type 3 3 3 3 3W N PE 3W N PE 3W N PE 3W N PE Protection devices DC...

Страница 30: ...current 11 7A 13 3A 15A Rated AC output power 7kW 8kW 9kW Max AC apparent power 7 7kVA 8 8kVA 9 9kVA 33A 33A 33A 16A 20A 25A 310 476V 310 476V 310 476V 2 1 1 2 1 1 Efficiency Max efficiency 98 3 98 3...

Страница 31: ...age 160V 160V 160V PV voltage range 160V 1000V 160V 1000V 160V 1000V MPP voltage range DC nominal voltage 200V 1000V 600V Max PV Isc 16A 16A 16A 16A 16A 16A Number of independent MPP trackers strings...

Страница 32: ...monitoring unit yes yes yes General Data Dimensions W H D in mm Weight Operating temperature range 25 C 60 C 13 F 140 F With derating above 45 C 113 F Noise emission typical 35 dB A 480 448 200 22kg 2...

Страница 33: ...current 19A 20 6A 23 8A Rated AC output power 12kW 13kW 15kW Max AC apparent power 13 2kVA 14 3kVA 16 5kVA 44A 44A 44A 25A 32A 32A 310 476V 310 476V 310 476V 2 2 1 2 2 1 Efficiency Max efficiency 98 3...

Страница 34: ...tion night 0 5 W 11 2 DC connector info DC connector Specification 11 3 Torque Values Enclosure lid screws 0 7Nm 6 2 1bf in Shell and RS232 screws 0 7Nm 6 2 1bf in AC terminal 0 6Nm 5 2 1bf in M6 sock...

Страница 35: ...or your dealer Name Description Communication interface Wi Fi Communication interface Shine WebBox Communication data logger Shine Vision receiver Communication data logger receiver Shine Vision emitt...

Страница 36: ...14 Contact If you have technical problems concerning our products contact your installer or manufacturer During inquiring please provide below information 1 Inverter type 2 Modules information 3 Commu...

Страница 37: ...TL3 S Growatt 7000TL3 S Growatt 11000TL3 S Growatt 13000TL3 S Growatt 15000TL3 S Installation Operation Manual Shenzhen Growatt New Energy Technology CO LTD No 28 Guangming Road Longteng Community Shi...

Страница 38: ...3 4 Transportation Unpacking Index 1 2 3 4 2 2 Safety Precautions Installation 5 5 1 Safety instruction 5 2 Selecting the Installation Location 2 3 Assembly Warnings 2 4 Electrical Connection Warning...

Страница 39: ...the Inverter 8 2 Checking the DC Disconnect Trouble shooting 9 10 1 Dismantling the Inverter 10 2 Packing the Inverter Decommissioning 10 10 3 Disposing of the Inverter Specification 11 Certificates...

Страница 40: ...indicates a hazardous situation which if not avoided could result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury NOTIC...

Страница 41: ...r coupling capacity does not exceed 2 2uF During feed in operation a leakage current flows from the cells to earth the size of which depends on the manner in which the PV modules are installed e g foi...

Страница 42: ...AC current generated as follows 5 6 2 2 Safety Precautions The TL3 S series Inverter is designed and tested according to Internalational safety requirements however certain safety precautions must be...

Страница 43: ...ply with all corresponding safety symbols and markings present on the unit and in this manual In special cases there may still be interference for the specified application area despite maintaining st...

Страница 44: ...ty should be always between 0 and 95 If there are lots of inverters need to be stored the maximum layers for original carton is four After long term storage local installer or service department of ma...

Страница 45: ...imit values e g when sensitive equipment is located at the setup location or when the setup location is near radio or television receivers In this case the operator is obliged to take proper action to...

Страница 46: ...c panel is exposed to light it generates a DC voltage When connected to this equipment a photovoltaic panel will charge the DC link capacitors Energy stored in this equipment s DC link capacitors pres...

Страница 47: ...you need to hang on the inverter During the process please maintain the balance of the TL3 S Hang the inverter on the expansion bolt After confirming the inverter is stuck on expansion bolt fasten fo...

Страница 48: ...re to the sunlight may cause additional internal heating which will cause power derating More than one inverter need to be installed the dimensions below should be considered Fig5 6 Fig5 7 Fig 5 8 Rec...

Страница 49: ...ly disconnected under load Measure the public grid voltage and frequency Voltage 400Vac Frequency 50Hz 60Hz 3 Phase Open the breaker between the PV inverter and utility Specification of AC breaker Cab...

Страница 50: ...he inverter To reduce the risk of electric shock avoid touching the live components and treat the terminals carefully Information Please use the same brand male and female PV connectors Under any cond...

Страница 51: ...nverter 4 The maximum string currents are varying from different inverter types Model Max current 7000TL3 S 8000 9000TL3 S 10000 11000TL3 S 12000TL3 12000 15000TL3 S 11 5A 11 5A 11 5A 11 5A 13A 13A 11...

Страница 52: ...nal system Notes The inverter starts up automatically when DC power from the PV panel is sufficient Fault Mode The internal intelligent controller can continuously monitor and adjust the system status...

Страница 53: ...afety standard must be selected by the DIP switch The DIP switch is composed of four digit binary number PINS The different combination of the four PINS can represent different inverter s model which...

Страница 54: ...4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 AS4777_Newzealand GT1XXXXXX0 Reserved GT1XXXXXX1 India GT1XXXXXX2 EN50438_Demark GT1XXXXXX3 EN50438_Sweden GT1XXXXXX4 EN50438_Norway G...

Страница 55: ...l 2000 Kwh AC Volt A B C 230V 230V 230V Set Language Set Language English Once Once Once Double Fig6 3 Overall display interface Power on display After inverter restarts the background light will last...

Страница 56: ...Com Address 001 Set Language Set Date Time AC V Control Disable Enable Once Once Once Setting Three Set Language English Double AC V Control Disable Double Double Date 2012 04 05 Time 14 20 38 Settin...

Страница 57: ...ime Date 2013 05 06 Time 14 20 38 Date 2013 05 06 Time 14 20 38 Date 2013 05 06 Time 15 20 38 Date 2013 05 06 Time 15 20 38 Date 2013 05 06 Time 15 21 38 Set OK Double Once Double Once Double Once Dou...

Страница 58: ...ication systems You can update firmware via RS232 or Rs485 The connecting diagram as follow Active power control with a ripple control signal receiver Through RS485 interface RS485 232 RS232 converter...

Страница 59: ...RS485 cable connection Rs485 cable connection Pin1 TR B Pin2 Shielding layer or no connection Definitions of RS485 PLUG standard as follows Pin1 TR B Pin2 Shielding layer or no connection Pin3 TR A P...

Страница 60: ...recommended as STP FTP ASTP 4 Plug in two terminals Cover the fix board Information Tighten 4 pcs screws first then tighten cable gland 5 Tighten 4pcs screws and cable gland Note 1 As to the connecti...

Страница 61: ...off the DC switch of the inverter 3 Check the inverter operating status 4 Until the display of LCD goes out the inverter is shut down Once the output power is derating because of too high warming some...

Страница 62: ...acing inverter Error message Description Suggestion Error 124 No AC connection Check AC wiring Check the status of AC breaker PV Isolation Low Insulation problem 1 Check if panel enclosure ground prop...

Страница 63: ...oblem still exist Contact Growatt Warning 109 Warning 108 PV 1 or PV2 Circuit short PV 1 or PV2 boost broken Check the PV panel polarity Restart the inverter If the warning still exist please contact...

Страница 64: ...he installation site at that time Ensure that the old unit and where applicable any accessories are disposed of in a proper manner 11 Specification 11 1 Specification of TL3 S Model 7000TL3 S 8000TL3...

Страница 65: ...ency 99 5 99 5 Power factor at rated power 1 1 1 Adjustable displacement power factor THDi Full load THDv 1 0 8leading 0 8laging AC grid connection type 3 3 3 3W N PE 3W N PE 3W N PE Protection device...

Страница 66: ...x output current 16 7A 18 3A 19A Rated AC output power 10kW 11kW 12kW Max AC apparent power 11kVA 12 1kVA 13 2kVA 33A 33A 44A 25A 25A 25A 184 300V 184 300V 184 275V Efficiency Max efficiency 98 3 98 3...

Страница 67: ...Voltage 160V 160V 160V PV voltage range 160V 1000V 160V 1000V 160V 1000V MPP voltage range DC nominal voltage 200V 1000V 600V Max PV Isc 16A 16A 16A 16A 16A 16A Number of independent MPP trackers str...

Страница 68: ...ated all pole sensitive leakage current monitoring unit yes yes yes General Data Dimensions W H D in mm Weight Operating temperature range 25 C 60 C 13 F 140 F With derating above 45 C 113 F Noise emi...

Страница 69: ...ture range 40 to 90 Strip length 7 0mm 9 32 Cable jacket diameter 4 5 to 7 8mm 3 16 to 5 16 Rated current at 90 Additional ground screws 2Nm 181bf in 11 4 Spare Parts and Accessories In the following...

Страница 70: ...0438 G83 G59 CE IEC62109 NB T32004 2013 G59 14 Contact If you have technical problems concerning our products contact your installer or manufacturer During inquiring please provide below information 1...