© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Basic Installation/Operation
21
70421501 (EN)
120 Pound Tumble Dryers
Figure 3
TMB2014N
NOTE: Refer to
for sizing of steam lines. Piping must also be sized accordingly for length of runs and number
of elbows.
1
Supply
8
457 mm (18 in.) Drop
2
305 mm (12 in.) Riser
9
Solenoid Valve (Supplied with machine)
3
Shut-Off Valve
10
Steam Bonnet
4
Condensate Return Line from Supply Line
11
Flexible Line
5
Return
12
Union
6
Check Valve
13
Trap with Built-in Strainer
7
Vacuum Breaker (optional)
Model
Steam Pressure
bar (PSI)
Minimum Pipe Diameter
Steam Trap Size*
(Pounds Condensate/Hour)
120S
8.3 - 8.6 (120-125)
1 in. NPT
345
4.1 - 8.3 (60-120)
1 in. NPT
345
2.4 - 4.1 (35-60)
1-1/4 in. NPT
345
*Based on maximum PSI.
Table 3
TMB2014N
2
12
6
3
5
1
13
10
9
8
6
7
4
11