Fault/cause/remedy
Fault
Cause
Remedy
LED in electronics flashing
continuously after
calibration
• Obstacle during calibration
- Perform calibration again, ensuring there is no
obstacle in the adjustment range of the servo
motor
• Servo motor defective
- Replace servo motor
No flushing
• No voltage (LED in electronics not
flashing)
- Switch on power supply or replace transformer
• Electronics defective (LED not flashing or
permanently on)
- Replace electronics
• Servo motor defective
- Replace servo motor
• Plug-in connector without contact
- Attach plug-in connector
• Detection zone of sensor system set too
low
- Increase detection zone using remote control
(special accessories 36 407)
• Servo motor and electronics not calibrated - Calibrate servo motor
• No flushing with manual actuation
- Connect or check pneumatic hose
Water flowing
continuously
• Waste not closing
- Maintain or replace waste, see technical
product information for cistern
- Calibrate servo motor
Undesired flushing
• Detection zone of sensor system set too
high
- An opposing object is detected. Reduce
detection zone using remote control
(special accessories 36 407)
Flow volume too low
• Servo motor defective or not calibrated
(incomplete rotation)
- Replace or calibrate servo motor
• Residual flow rate in cistern too high
- Push residual flow slider at waste downwards
• Flow rate in cistern too low
- Turn float of filler valve upwards