4
Carbonate hardness
Bypass
Litre capacity
A
B
40 404 001
40 430 001
40 412 001
≤
9 (°KH)
≤
16 (°fH)
≤
3,38
≤
1,69
3
1.600 l
4.000 l
6.500 l
10 - 24 (°KH)
17 - 43 (°fH)
3,39 - 8,75
1,7 - 4,37
2
600 l
1.500 l
2.300 l
25 - 29 (°KH)
44 - 52 (°fH)
8,76 - 10,35
4,38-5,22
1
350 l
1.000 l
1.500 l
≥
30 (°KH)
≥
53 (°fH)
≥
10,36
≥
5,33
0
250 l
650 l
1.000 l
Fault
Cause
Remedy
Water too cold
• Empty storage heater switched on
(‘On’ indicator lamp flashes)
• Heating phase not yet complete
- Fill the storage heater, see section
Installation
Reset the storage heater by pressing the reset
button (X) located on the rear of the storage heater
using a thin object, see fold-out page IV, Fig. [22]
- Wait max. 15 minutes
Flow rate too low
• Fitting flow straightener dirty or defective
• Isolating valve not fully open
• Water supply restricted
- Replace flow straightener, see section
Maintenance
- Fully open shut-off valves, isolating valves
- Check supply lines, open isolating valve
Water not boiling
• Storage heater not hot enough yet
- Wait approx. 15 minutes after switching on
Storage valve losing
water
• Hose connection or internal tank leaking
- Switch off the storage heater, disconnect the mains
plug and contact GROHE Customer Service
Splashy, irregular
spray
• Fitting flow straightener dirty or defective
- Replace flow straightener, see section
Maintenance
Fitting running
continuously
• Handle not closing
- Close the isolating valves, switch off the storage
heater, disconnect the mains plug and contact
GROHE Customer Service