background image

D

.....1

I

.....5

N

.....9

GR

.....13

TR

.....17

BG

.....21

RO

.....25

GB

.....2

NL

.....6

FIN

.....10

CZ

.....14

SK

.....18

EST

.....22

CN

.....26

F

.....3

S

.....7

PL

.....11

H

.....15

SLO

.....19

LV

.....23

RUS

.....27

E

.....4

DK

.....8

UAE

.....12

P

.....16

HR

.....20

LT

.....24

 Engineering GROHE Germany

GROHE Red 

Duo

GRO

H

E R

e

Duo

99.133.231/ÄM 230155/04.14

30 058
30 153

GB

.....1

I

.....5

N

.....9

GR

.....13

TR

.....17

BG

.....21

RO

.....25

DK

.....6

NL

.....6

FIN

.....10

CZ

.....14

SK

.....18

EST

.....22

CN

.....26

F

.....3

S

.....7

PL

.....11

H

.....15

SLO

.....19

LV

.....23

RUS

.....27

E

.....4

DK

.....8

UAE

.....12

P

.....16

HR

.....20

LT

.....24

Содержание Red Duo 30 058

Страница 1: ... 19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Design Engineering GROHE Germany GROHE Red Duo GROHE Red Duo 99 133 231 ÄM 230155 04 14 30 058 30 153 GB 1 I 5 N 9 GR 13 TR 17 BG 21 RO 25 DK 6 NL 6 FIN 10 CZ 14 SK 18 EST 22 CN 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 ...

Страница 2: ...I 30 058 30 153 Please pass these instructions on to the end user of the fitting ...

Страница 3: ...II 1 13mm 19 017 A max 60mm max 45mm A 7 Ø8 2 2 24mm 31mm G1 2 G3 8 31mm 24mm B B 9 C 10 8 10mm 4 Ø40 Ø32 5 6 3 min 50 284 ...

Страница 4: ...rooms The boiling water storage heater is only suitable for indoor use The boiling water storage heater must be placed in an upright position The boiling water storage heater and plug must not be directly or indirectly sprayed with water when cleaning The boiling water storage heater must not be opened Use only genuine replacement parts and accessories The use of other parts will result in voiding...

Страница 5: ...he Ø15mm compression connection J of the expansion vessel C and tighten Connecting fitting see fold out page III Fig 14 1 Screw fitting pressure hose K marked blue to adapter G 2 Screw red marked pressure hose L of the fitting onto the hot water service valve 3 Connect the fitting pressure hose M marked 99 C to connection N on the storage heater Open the service valve and check connections for wat...

Страница 6: ... page IV Fig 21 1 Lever out plug T and remove set screw U 2 Remove lever R and cap V 3 Remove screw coupling W and take out cartridge S Assemble in reverse order When installing the cartridge S ensure that the seals are correctly seated Screw in screw coupling W and tighten III Flow straightener Remove and clean flow straightener 13 263 see fold out page I Assemble in reverse order Service Note th...

Страница 7: ... 22 Wait max 15 minutes Flow rate too low Fitting flow straightener dirty or defective Isolating valve not fully open Water supply restricted Replace flow straightener see section Maintenance Fully open shut off valves isolating valves Check supply lines open isolating valve Water not boiling Storage heater not hot enough yet Wait approx 15 minutes after switching on Storage valve losing water Hos...

Страница 8: ......

Страница 9: ......

Страница 10: ...III E D 19mm F 19mm OUT IN 11 D E G H 19mm 19mm 12 19mm H I C 24mm 19mm 13 J Ø15mm O1 O R 15 Q1 Q P 2sec 16 N K M G 19mm 19mm L 19mm 14 ...

Страница 11: ...IV X 22 17 F 18 F2 F3 19 F1 20 S 21 W R T U 30mm 3mm V ...

Страница 12: ...30 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 bLuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com R...

Отзывы: