6
Maintenance
Inspect and clean all components and replace if necessary.
Use the cistern TPI to maintain the cistern parts.
Replacing the switched-mode power supply
, see fold-out
page III, Fig. [25].
1. Switch off voltage supply.
2. Disconnect extension cable (D) from upper part (A3).
3. Detach upper part (A3) of the switched-mode power supply.
4. Locate and engage new upper part.
5. Connect upper part (A3) to extension cable (D).
6. Switch on voltage supply.
Replacing the servo motor
,
see fold-out page III
Shut off water supply.
1. Remove wall plate, see Fig. [23].
2. Disconnect plug-in connectors from electronics (C) to
extension cable (D) and to servo motor (P), see Fig. [26].
3. Detach lift rod (O) from lever (P2), see Fig. [27].
4. Remove bracket with servo motor (P) from crossrail (U).
5. Calibrate new servo motor, see
Calibrating the
servo
motor
.
6. Install new servo motor, see
Installing the servo motor
.
7. Install wall plate, see
Installing the wall plate
.
Replacing the wall plate with electronics
,
see fold-out
page III
1. Remove wall plate, see Fig. [23].
2. Disconnect plug-in connectors from electronics (C) to
extension cable (D) and to servo motor (P), see Fig. [26].
Assemble in reverse order.
Replacement parts
,
see fold-out page I (* = special
accessory).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault / Cause / Remedy
Fault
Cause
Remedy
Illuminated frame not lighting
• Power failure
- Reconnect power supply
• Switched-mode power supply defective
- Replace switched-mode power supply,
see
Replacing the switched-mode power
supply
• Plug-in connector without contact
- Attach plug-in connector
• Lighting switched off
- Switch on lighting, see
Switching on the
lighting using button T1
• Timer not activated
- Activate timer, see
Activating the timer
using button T1
Illuminated frame is not
switched on at desired time
• Incorrect time set
- Set time, see
Setting the time
• Incorrect start time set for lighting
- Set start time for lighting, see
Setting
the start time for lighting
• Extended power failure (more than 1 hour) - Reset time, see
Setting the time
• Summer/winter time changeover
- Reset time, see
Setting the time
Illuminated frame lighting for
too long/not long enough
• Incorrect lighting duration set
- Set lighting duration, see
Setting the
lighting duration
Illuminated frame not lighting
with correct colour
- Select and store lighting colour again,
see
Selecting the colour using button T3
and Switching the colour using button T2
Illuminated frame not lighting
• Incorrect start time set for lighting
- Set start time for lighting, see
Setting the
start time for lighting
• Incorrect lighting duration set
- Set lighting duration, see
Setting the
lighting duration
• Continuous lighting set
- Activate timer, see
Activating the timer
using button T1
4 LEDs flashing continuously
• The timer is activated and the time is no
longer correct due to an extended power
failure
- Deactivate timer,
using button T1
and
reset time, see
Setting the time
Содержание Ondus 38 915
Страница 3: ...II K2 L M N1 N 3 2 1 10 13 12 K1 O 3 4 2 1 P1 P 14a 14b 15 16 17 K1 K 7 8 9 11...
Страница 37: ...34 UAE...
Страница 38: ...35...
Страница 39: ...36...
Страница 42: ...39 TPI 25 1 2 D 3 3 3 4 5 A3 D 6 III 1 23 2 C D 26 3 2 27 4 U 5 6 7 1 23 2 C D 26 I 1 1 3 2 1 4 LED 1...
Страница 84: ...81 25 1 2 D A3 3 A3 4 5 3 D 6 1 23 2 D 26 3 O P2 27 4 P U 5 6 7 III 1 23 2 D 26 I 1 1 T3 T2 1 4 T1...
Страница 88: ......
Страница 89: ......
Страница 90: ...III P P2 3 2 1 C D 90 P2 C D 19 18 U 2 1 P 20 D O P2 C 2 1 21 22 23 24 25 D P C 26 27 U P 3 2 1 P2 O...
Страница 91: ...IV...