1
English
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is
not
possible.
Specifications
•
Max. flow
5.7 L/min or 1.5 gpm/60 psi
•
Flow pressure
- min.
7.25 psi
- recommended
14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure
reducing valve
•
Max. operating pressure
145 psi
•
Test pressure
232 psi
•
Temperature
- max. (hot water inlet)
176
°
F
•
Water connection
hot - LH
cold - RH
•
Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush piping system prior and after installation of
faucet thoroughly!
Mount faucet on basin
See dimensional drawing fold-out page I.
For installation, see fold-out page III, figs.[1], [2] and [3].
Lift rod (A) must be inserted into the mixer body during
installation.
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see figs. [1]
and [3].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
Fit pop-up drain (28 957),
see fold-out page II, ensure
that flange of pop-up drain is sealed.
Open angle stops and check faucet for correct
function,
see fig. [4].
Lift lever
= open (water flow)
Press lever down
= closed (off)
Move lever to right
= cold water
Move lever to left
= hot water
Check connections for leakage.
Temperature limiter
On delivery, the temperature limiter (fitted as standard)
is inoperative.
For commissioning see “replacing the cartridge”
point 1 to 3, fig. [6].
Remove temperature limiter (B) and depending on the
maximum temperature required, turn anticlockwise (to
increase temperature) or clockwise (to reduce
temperature) and refit, see fold-out page III, figs. [5]
and [6].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge,
see fig. [6].
1. Lever out plug (C).
2. Remove set screw (D) using a 3mm socket wrench
and pull off lever (E).
3. Pull off cap (F).
4. Turn out screwing (G) with key 27mm.
5. Change complete cartridge (H).
Assemble in reserve order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the
grooves and the locating pins at the base of the
cartridge slot into the apertures on the housing.
Screw in and tighten screwing (G).
II. Flow regulator,
see fold-out page II.
Unscrew and clean flow regulator (48 159).
Assemble in reverse order.
Replacement parts,
see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.
Содержание Eurocube 23 129
Страница 3: ...II ...