3
GB
Application
Surface mounted thermostatic mixers are designed for hot
water supply via pressurized storage heater and utilized in this
way provide the best temperature accuracy. With sufficient
power (from 18 kW or 250 kcal/min) electric or gas
instantaneous heaters are suitable.
Thermostats cannot be used in connection with low pressure
storage heaters.
All thermostats are adjusted in the plant at a flow pressure on
both sides of 3 bar.
If temperature deviations should exist due to special
installation conditions, then the thermostat is to be adjusted to
the local conditions (see Adjustment).
Specifications
Minimum flow pressure without
downstream resistances
0.5 bar
Minimum flow pressure with
downstream resistances
1 bar
Max. working pressure
10 bar
Recommended flow pressure
1 - 5 bar
Test pressure
16 bar
Flow rate at 3 bar flow pessure
approx. 27 l/min
Max. water temperature at hot water inlet
80 °C
Recommended max. stored
temperature (energy saving)
60 °C
Safety check
38 °C
Hot water temperature at supply connection
min. 2 °C higher than mixed water temperature
Cold water connection
right
Hot water connection
left
Minimum flow rate
= 5 l/min
At a flow pressure over 5 bar it is recommended that a
pressure reducing valve be fitted in the supply line.
Installation
Flush piping system prior and after installation of fitting
thoroughly
(Consider EN 806)
!
Install S-unions and fit mixer,
for required dimensions
, see
fold-out page I, Fig. [1].
1. Install the S-unions and sleeve, preassembled with the
escutcheon.
2. Screw-mount the mixer and check connections
for leakage.
3. Push the sleeve with escutcheon onto the union nut.
4. Screw the escutcheon flush against the wall.
Refer to the dimensional drawing on fold-out page I.
Reversed union
(hot on right - cold on left).
Replace thermoelement (A), see replacement parts fold-out
page II, ref. No. 47 657 (1/2”).
Adjustment
For temperature-adjustment,
see figs. [2] and [3].
• Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat.
• After any maintenance operation on the thermostatic
cartridge.
1. Open the shutt-off valve and check the temperature of the
water with a thermometer, see fig. [2].
2. Lever out cap (B), see fig. [3].
3. Unscrew screw (C).
4. Pull off temperature control handle (D).
5. Turn adjusting nut (E) until the water temperature
reaches 38 °C.
6. Install temperature control handle (D) in such a way that the
button (G) facing the front.
7. Reinstall screw (C).
8. Fit cap (B) back on.
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be
overridden by pressing the button (G).