2
English
Connect CO
2
cylinder
, see Figs. [8] to [12].
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
will escape
, see Fig. [9].
- The valve is only needed when cleaning the cooler/
carbonator.
The faucet has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
If the Blue
®
handle is flashing red and E4 or E6 appears in
the display, the faucet and cooler/carbonator must be
synchronised as follows,
see Fig. [13]
:
• Press and hold the
and
c
buttons simultaneously until
SE
flashes in the display.
• Press the
button until
SE
stops flashing.
• Release the
button,
C-
flashes in the display.
• Keep pressing the
U
or
c
button until
H-
flashes in the
display.
• Press the
button until
H-
stops flashing.
• Blue
®
handle synchronisation starts;
HC
appears in the
display and the Blue
®
handle lights up
red
.
• As soon as the Blue
®
handle lights up
green
, open the
faucet fully by turning the Blue
®
handle.
• As soon as the Blue
®
handle briefly flashes
green
, close the
faucet by turning the Blue
®
handle,
HC
flashes in the
display.
• Confirm the setting by pressing the
button longer,
HC
appears.
• Release the
button.
The remaining filter capacity is displayed.
Commissioning
Control,
see fold-out page II, Fig. [13].
The buttons have the following functions:
Filter replacement reset
U
Filter size selection
c
Carbonate hardness adjustment
Display,
see Fig. [13].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator,
see Fig. [14].
Set the filter size
,
see Fig. [13].
U
button for filter size selection:
• Press and hold
U
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
U
button and select the required value appears
- F1:
600 liters / 159 gallons
40 404 000
- F2:
1,500 liters / 396 gallons
40 430 000
- F3:
3,000 liters / 793 gallons
40 412 000
- F4:
600 liters / 159 gallons
40 404 001
- F5:
1,500 liters / 396 gallons
40 430 001
- F6:
3,000 liters / 793 gallons
40 412 001
- F7:
- F8:
3,000 liters / 793 gallons
40 547 001
(Activ carbon)
• Press and hold the
U
button until the required value stops
flashing
• Release the
U
button:
The remaining filter capacity is displayed.
Note: The various filter cartridges
can be ordered at
www.grohe.com
.
Set carbonate hardness at filter head
, see Fig. [15].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column
A
on fold-out page III.
Display and setting of carbonate hardness on cooler/
carbonator
, see table column
B
on fold-out page III
and
Fig. [13].
c
button for carbonate hardness adjustment:
• Press and hold the
c
button once until the currently setted
value (e. g. C3) flashes in the display
• Press the
c
button and select the required value:
- C4: carbonate hardness
≤
9
(bypass 3)
- Factory setting:
C3: carbonate hardness
10 - 24
(bypass 2)
- C2: carbonate hardness
25 - 29
(bypass1)
- C1: carbonate hardness
≥
30 (bypass
0)
• Press and hold the
c
button until the setted value stops
flashing
• Release the
c
button.
The remaining filter capacity is displayed.
The liter capacity of the filter cartridge varies according to the
water hardness set and the size of the filter cartridge, see table
on fold-out page II.
The cooler/carbonator is set for operation with the 159 gallons
filter cartridge (Prod no.: 40 404 001) at the factory.
For operation with other filter cartridges the cooler/carbonator
must be set out.
The faucet with cooler/carbonator is now fully installed and
ready for operation.
Maintenance
Resetting filter capacity after changing filter cartridge
, see
fold-out page II, Fig. [13].
button for filter replacement reset:
• Press and hold
button until
rF
flashes in the display.
• Release the
button and press again until
rF
stops
flashing.
• Release the
button.
The remaining filter capacity is reset and then displayed
again.
Restore factory settings
,
see Fig. [13].
Reset
U
c
buttons to factory settings:
• Press and hold the
U
c
buttons simultaneously until
PA
starts flashing in the display.
• Release the
U
c
buttons.
The remaining filter capacity is displayed.
Important:
Risk of damage!
Always disconnect the power supply
and interrupt
the
CO
2
supply before carrying out maintenance work
on the system. The plug-in connector can then be
disconnected
, see fold-out page II, Figs. [6] and [7].
Inspect and clean all components and replace if necessary.
Assemble in reverse order.
Cleaning cooler/carbonator
For hygienic and healthy reasons, the cooler/carbonator
must be cleaned once a year. Cleaning must be
performed before changing the filter cartridge, in order to
prevent contamination of the replacement filter cartridge.
Note: The cleaning kit
(Prod. no.: 40 434 001) and the
accompanying adapter (Prod. no.: 40 694 000 or 40 699 000)
could be ordered at
www.grohe.com
.