2

- The indicator in the handle of the fitting illuminates red

1. Wait until the display switches to green.
2. Fully open handle by turning through 90°.
3. Wait until the green light is briefly interrupted and the 

water begins to flow.

4. Close handle, display illuminates blue.

Flush filter cartridge

, see fold-out page III, Fig. [12].

Open handle and press flush button on the filter head in 
order to flush the filter system. Continue flushing until the 
water emerging from the hose is clear and free of bubbles 
(at least 2 litres).

Operation / Commissioning

Open 

lever

 in order to draw hot and cold tap water, see 

fold-out page III, Fig. [13].

Open 

handle 

to draw off filtered GROHE Blue

®

 

water.

Control unit

,

 

see fold-out page II, Fig. [11].

The buttons perform the following functions:

Filter replacement reset

U

Filter size selection

c

Carbonate hardness adjustment

Display

,

 

see fold-out page II, Fig. [11].

In the inactive state, the remaining filter capacity is displayed 
in percent.

Display of filter capacity in handle:

Set carbonate hardness at filter head

, see Fig. [14].

The relevant water supplier can provide information on the 
carbonate hardness.
The filter head can be swivelled forwards by up to 90° in the 
wall holder to install the cartridge.
Set carbonate hardness at bypass setting of filter head to local 
conditions, see table column A on page 3.
The set value for water hardness must also be set in the 
control unit, see section 

Putting into service

.

Setting carbonate hardness on control unit

, see table 

column B on page 3 and Fig. [11] on fold-out page II.

c

 button for carbonate hardness adjustment:

• Press the 

c

 button once: 

The display switches from the remaining filter capacity to the 
value currently set for the carbonate hardness.

• Keep the 

c

 button pressed: 

After approx. 3 seconds, the value currently set for the 
carbonate hardness starts to flash.

• Release the 

c

 button within the next 10 seconds: 

The value currently set for the carbonate hardness starts to 
flash.

• Press the 

c

 button and select the required value:

- C1:  carbonate hardness 

25 - 35  (bypass 20%)

- C2:  carbonate hardness 

18 - 24  (bypass 30%)

- Factory setting:
  C3:  carbonate hardness  14 - 17  (bypass 40%)

- C4:  carbonate hardness 

12 - 13  (bypass 50%)

- C5:  carbonate hardness 

10 - 11 

(bypass 60%)

- C6:  carbonate hardness 

  7 - 9 

(bypass 70%)

•  Press and hold the 

c

 button at the required value 

for 3 seconds: 
The display of the value switches from flashing to 
continuous illumination and the value is set.

Release the 

c

 button: 

The remaining filter capacity is displayed again:

The litre capacity of the cartridge varies according to the 
water hardness set and the size of the cartridge, see table 
on page 3.

The control unit of the GROHE Blue

®

 fitting is set for operation 

with the 600 litre filter cartridge (Prod no.: 40 404) at the 
factory.

For operation with the 3,000 litre filter cartridge 
(Prod. no.: 40 412) or 1,500 litre filter cartridge 
(Prod no.: 40 430) the control unit must be adapted.

Setting filter size

,

 

see fold-out page II, Fig. [11].

U

 button for filter size selection:

• Press 

U

 button once. 

The display switches from the remaining filter capacity to the 
value currently set for the filter size.

• Keep the 

U

 button pressed: 

After approx. 3 seconds, the value currently set for the filter 
size starts to flash.

• Release the 

U

 button within the next 10 seconds: 

The value currently set for the filter size starts to flash.

• Press the 

U

 button and select the filter size:

- F1: 

600 litres 

- F2: 

1,500 litres 

- F3: 

3,000 litres 

•  Press and hold the 

U

 button at the required value 

for 3 seconds: 
The display of the value for the filter size switches from 
flashing to continuous illumination and the filter size is set.

Release the 

U

 button: 

The remaining filter capacity is displayed again:

The fitting is now fully installed and ready for operation.

Note: The various filter cartridges 

can be ordered at 

www.grohe.com

.

Maintenance

Resetting filter capacity after changing filter cartridge

,

 

see 

fold-out page II, Fig. [11].

 button for filter replacement reset:

The remaining filter capacity is displayed:
• Press   button 

The display switches from the remaining filter capacity to 

rF

.

• Keep the   button pressed: 

After approx. 3 seconds, 

rF

 starts to flash.

• Release the   button within the next 10 seconds and press 

again: 

rF

 flashes first and then illuminates continuously.

• Release the   button: 

The remaining filter capacity is reset and then displayed 
again.

Warning

Risk of damage:

Always disconnect the power supply before performing 
maintenance work on the system. The plug-in connectors 
can then be disconnected

, see fold-out page II, Fig. [7].

Inspect and clean all components and replace if necessary.

I. Cartridge

, see fold-out page III, Fig [15].

Assemble in reverse order. When installing the cartridge, 
ensure that the seals are correctly seated. Replace screw 
coupling and tighten.

Flashing signal

Meaning

Filter capacity of more than 10%

  

Filter capacity of less than 10%
Order filter cartridge

 

 

Filter capacity of less than 1%
Change filter cartridge soon

         

No filter capacity Change filter 
cartridge 

immediately