Grohe Blue 31 087 Скачать руководство пользователя страница 4

1

GB

GB

Application

Can be used in conjunction with:
•  Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement 
water heaters) is 

not

 possible.

The filter head is fitted with a type-tested non-return valve.

The water filtrate is classified as Category 2 according 
to EN 1717.

Safety notes

Avoid danger due to damaged power cords. In the 
case of damage, the control unit must be replaced by 
the manufacturer or his customer service department 
or an equally qualified person.

•  For hygiene reasons, the filter system 

must

 be flushed 

before using for the first time.

• The filter system 

must always

 be operated with cold water 

of foodstuff grade.

• The filter head 

must

 be replaced after 5 years.

• The control unit and plug must 

not

 be directly or indirectly 

sprayed with water when cleaning.

•  The control unit 

must

 be connected to a permanent power 

supply.

•  At the installation location, the filter system 

must

 be 

protected against mechanical damage, heat and direct 
sunlight. 

Do

 

not

 install near heat sources or an open fire.

•  Installation of the fitting with filter cartridge is 

only permitted

 

in frost-free rooms.

• Use 

only genuine replacement parts and accessories

The use of other parts will result in voiding of the warranty 
and the CE identification.

Technical data

Electrical data:

• Voltage supply: 

100 - 240 V AC / 50/60 Hz

• Power consumption: 

9 W

• Standby power loss: 

 < 1.0 W

• Type of protection

– Control unit:

IP 68

– Mains plug:

IP 40

Sanitary data:

• Flow pressure:

– min.

0.1 MPa (1 bar)

– recommended

0.2 – 0.5 MPa (2 – 5 bar)

• Operating pressure

– Fitting:

max. 0.8 MPa (8 bar)

– Filter cartridge and filter head:

0.2 – 0.8 MPa (2 – 8 bar)

•  Test pressure of fitting:

1.6 MPa (16 bar)

If static pressures exceed 5 bar, a pressure-reducing valve 
must be installed.
Avoid major pressure differences between hot and cold water 
supply.
•  Flow rate at 3 bar flow pressure

– Fitting (tap water):

approx. 9 l/min

– Filter cartridge (GROHE Blue

®

 water):

approx. 4.5 l/min

•  Ambient temperature:

4 – 32 °C

• Temperature

– Hot water inlet:

max. 70 °C

– Recommended (energy saving):

 60 °C

•  Adjustable bypass, factory setting:

 30%

•  Filter capacity at 40% bypass

(Carbonate hardness 14 - 17 °KH):

max. 600 litres

corresponds to max. 12 months

• Water connection:

cold - blue

hot - red

Electrical test data

• Software class:

A

• Contamination class:

2

•  Rated surge voltage:

2,500 V

•  Temperature for ball impact test:

100 °C

The test for electromagnetic compatibility (interference 
emission test) was performed at the rated voltage and rated 
current.

Approval and conformity

The conformity declarations can be obtained from the following 
address:

GROHE Deutschland Vertriebs GmbH

Zur Porta 9
D-32457 Porta Westfalica

Electrical installation

Electrical installation work must only be 
performed by a qualified electrician. This work 
must be carried out in accordance with the 
regulations according to IEC 364-7-701-1984 
(corresponding to VDE 0100 Part 701) as well 
as all national and local regulations.

Installation

Refer to the dimensional drawings on fold-out page I.

Install fitting

,

 

see fold-out page II, Figs. [1] and [2].

Important:

 The cable must not be pinched.

Flush pipes thoroughly before and after installation 

(observe EN 806)

!

Install filter cartridge

, see Figs. [3] to [5].

The filter head can be swivelled forwards by up to 90° in the 
wall holder to install the cartridge.
Use suitable screws and, if required, plugs.

Install control unit

, see Figs. [6] and [7].

Important:

 Do not connect voltage supply yet.

Connect fitting

, see Figs. [2], [8] to [10].

Open hot and cold water supply and check that 
connections are watertight.

Connect voltage supply via mains plug

, see Fig. [11].

The display illuminates and the remaining filter capacity is 
displayed in per cent.

During initial operation or if the plug-in connector has been 
disconnected, the fitting and the control unit must be 
synchronised as follows: 

This product conforms to the requirements of the 
relevant EU guidelines.

Отзывы: