Installation
Pipe Connection
1.Close free outlet with plug (K), see Fig. [9].
2.Thread the outlet nipple (L) with the O-ring
seal into the mixer body outlet.
3.Insert pipe and tighten outlet nipple (L).
Please refer to chapter "Maximum Hot
Water Limit Setting" on page 10 for limiting
maximum outlet temperature.
Open hot and cold water supply.
Check the pipework and connections to the
single lever mixer for leaks.
The single lever mixer is now ready for use.
Shower Hose Connection
1.Close free outlet with plug (K), see
Fig. [10].
2.Remove O-ring seal (L1).
3.Turn outlet nipple (L) 180
°
and fit O-ring
seal (L1).
4.Thread the outlet nipple with the O-ring
seal into the mixer body outlet.
5.Connect flexible shower hose.
Please refer to chapter "Maximum Hot
Water Limit Setting" on page 10 for limiting
maximum outlet temperature.
Open hot and cold water supply.
Check the pipework and connections to the
single lever mixer for leaks.
The single lever mixer is now ready for use.