2
GB
Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be replaced
by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in connectors must
not
be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use
only genuine replacement parts and accessories
.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off:
60 s
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
1 s
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20 cm adjustable):
12 cm
Thermal disinfection possible
Electrical test data
• Software class A
• Contamination class 2
• Rated surge voltage 2500 V
• Temperature of ball impact test 100 °C
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
Maintenance
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
Replacement parts
(* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault / Cause / Remedy
Fault
Cause
Remedy
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Clean filter
- Replace solenoid valve
- Check plug-in connector electronics and solenoid
valve
- Replace battery
Undesired water
flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
• Non-return valve defective
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Replace the non-return valve
Automatic flush
does not work
• Safety shutdown active
• Ambient conditions not suitable
- Remove object
- Check ambient conditions with remote control
(special accessory, order no.: 36 407) in test mode
at maximum range, LED must not light up.
5
b9916080.book Seite 2 Montag, 28. November 2022 1:38 13
Содержание 23975003
Страница 2: ...1 2 1 b9916080 book Seite 1 Montag 28 November 2022 1 38 13...
Страница 3: ...2 10 11 19mm 3 2 3 6 1 4 5 4 2b b9916080 book Seite 1 Montag 28 November 2022 1 38 13...
Страница 4: ...3 3 1 2 3mm 4 3 1 2 b9916080 book Seite 1 Montag 28 November 2022 1 38 13...
Страница 16: ...12 UAE 15 Novoflex Zebra XL Grey Card 36407 LED b9916080 book Seite 12 Montag 28 November 2022 1 38 13...
Страница 32: ...b9916080 book Seite 1 Montag 28 November 2022 1 38 13...