The AC15/AC25 can be programmed
by pressing and holding the manual
override button, located on the top of
the pump (see ‘B’, below right).
If the button is pressed for 10 seconds
the programming mode will be
activated and the LED (positioned in
viewing window ‘A’, below right) will
either flash Red or be continuously
Red (depending on the current
programming setting). The continuous
Red illumination or flashing of the
LED indicates that the pump is in the
programming mode and is showing the
current programming setting.
If the LED is continuously Red this
indicates that setting ’0’ is selected
(continuous run mode). If the button
is not pressed again within 30 seconds
the program will store this setting and
revert back to operating mode. The
pump will then ‘Run’ or operate on this
setting.
However, if the button is pressed and
released within 30 seconds the next
setting will be selected. See the table
above for setting details and timings.
For each setting the number of flashes
from the Red LED indicates the setting
selected. For example, for setting 1
the LED flashes Red once and delays
for 3 seconds, until flashing once
again. For setting 6 the LED will flash
Red six times before a 3 second delay
and it will—continue doing this for
30 seconds. The setting will then be
stored and the pump will operate to
the setting selected or, if the manual
override button is pressed again (within
30 seconds) the next setting will be
selected.
LED Flash patterns in programming mode
Setting 0
Setting 1
Setting 2
Setting 3
Setting 4
Setting 5
Setting 6
TIME
TIME
TIME
TIME
TIME
TIME
TIME
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
1s typ
3s typ
1s typ
1s typ
3s typ
1s typ
1s typ
3s typ
1s typ
1s typ
3s typ
1s typ
1s typ
3s typ
1s typ
1s typ
3s typ
A
B
Содержание Multiline AC Series
Страница 2: ...Copyright Groeneveld...
Страница 51: ......