background image

OM-NFPC

10

check such parts as the undersides of the
cover, the electrical console and other more

remote spots.  Clean between the pan
body and the control console using the
brush provided (P/N 058705).

g.

To remove materials stuck to the
equipment, use a brush, sponge, cloth,
plastic or rubber scraper, or plastic wool
with the cleaning solution.  To make
washing easier, let the cleaning solution sit
in the unit and soak into the residue, or
heat the solution briefly.  Do 

not

 use any

gritty cleaner or metal tool that might
scratch the surface.  Scratches make the
surface harder to clean, and also provide
places for bacteria to grow.  Do 

not

 use

steel wool.  Small bit of steel wool left in
the surface of the unit can cause rusting
and pitting.

h.

The outside of the unit may be polished
with a recognized stainless steel cleaner
such as Zepper from the Zep
Manufacturing Company.

i.

When the equipment needs to be
sanitized, use a sanitizing solution
equivalent to one that supplies 100 parts
per million available chlorine.  Get advice
about the best sanitizing agent from you
supplier of sanitizing products.  Following
supplier instructions, apply the sanitizing
agent after the unit has been cleaned and
drained.  Thoroughly drain off the sanitizer.

CAUTION

NEER  LEAVE  A  CHLORINE  SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES FOR LONGER THAN 30
MINUTES.  LONGER CONTACT CAN CAUSE
CORROSION.

j.

After the unit has been cleaned, sanitized
and drained, let all surfaces air dry unless
the unit must be used again right away.

k.

It is recommended that the unit be
sanitized just before use.  Follow the
directions of the sanitizer supplier.

l.

About once a week (more often if the
water is very hard), use a heavy duty
cleaner to remove any mineral deposits or
film left by hard water or foods.  Follow the
supplier’s directions very carefully, and
rinse the unit off thoroughly as soon as
cleaning is finished.

m. If especially difficult cleaning problems

persist, contact your cleaning product
supplier for help.  The supplier has a
trained technical staff with laboratory
facilities to serve you.

Maintenance

 

WARNING

USE OF REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE
TO  THE  EQUIPMENT  AND  WILL  VOID  ALL  WARRANTIES.  SERVICE  PERFORMED  BY
OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.

Your Braising Pan is designed to require
minimum maintenance, but certain parts may
require replacement after prolonged use.  After
installation, no user adjustment should be
necessary.  If a service need arises, only
authorized personnel should perform the work.

Service personnel should check the unit at least
once a year.  This should include inspecting
electrical wires and connections and cleaning
inside of the control console.  A Maintenance
and Service Log is provided at the rear of this
manual.  Each time work is performed, enter the
date on which it was done, what was done, and
who did it

.  

WARNING

ELECTRICAL POWER MUST BE SHUT OFF
BEFORE WORK IS DONE ON INTERNAL
COMPONENTS.

Содержание NFPC series

Страница 1: ...EL NFPC Braising Pan Stainless Steel Power Tilting Electrically Heated THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANU...

Страница 2: ...CONTACT WITH HOT FOOD OR WATER IN THE BRAISING PAN DIRECT CONTACT COULD RESULT IN SEVERE BURNS WARNING IF THE PAN CONTAINS ITEMS IN SAUCE OR MELTED FAT THEY COULD SLIDE FORWARD SUDDENLY DURING TILTING...

Страница 3: ...MATICS 13 MAINTENANCE LOG 22 WARRANTY 23 References ECONOMICS LABORATORY INC St Paul Minnesota 55102 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The N...

Страница 4: ...h on the front of the control console gives the operator positive smooth acting control of tilt Heating elements and other electrical components are enclosed for safety The thermostat heating indicato...

Страница 5: ...ower line A BX connection is not recommended CAUTION ELECTRICALLY GROUND THE PAN AT THE TERMINAL PROVIDED 3 Provide the proper electrical supply as specified on the electrical plate attached to the eq...

Страница 6: ...ermostat dial to the desired temperature between 100 and 400o F The glowing Heat Indicator Light shows that the pan is heating When the light cycles on and off it indicates that the pan is being held...

Страница 7: ...the horizontal position pull the switch up 6 If the power tilt mechanism stops working See the Trouble Shooting Section and you must raise or lower the pan body without delay you can tilt the body man...

Страница 8: ...for any reason a high limit thermostat shuts off the power until the pan cools At that point the thermostat automatically resets to permit normal operation to start again Turning the thermostat to OF...

Страница 9: ...CONTROLSANDELECTRICALEQUIPMENT DO NOT SPRAY OR HOSE THE CONTROL B O X O R O T H E R E L E C T R I C A L CONNECTIONS THEY ARE NOT WATER PROOF b To remove any large amount of food left in the pan tilt t...

Страница 10: ...tized and drained let all surfaces air dry unless the unit must be used again right away k It is recommended that the unit be sanitized just before use Follow the directions of the sanitizer supplier...

Страница 11: ...ps on the side of the control box Auth Service Rep Only c For loose or broken wire x d Thermostat functioning by listening for a click when the switch opens or closes x e Contactor functioning x Pan c...

Страница 12: ...nge Bracket 013485 5 Heater Strip 17 Bracket 004556 6 Fuse 6 Amp 003982 18 Actuator 045880 7 Fuse Holder 004326 19 Crank Manual Actuator 050242 8 Contactor Units after 1 1 85 006950 20 Thermostat Knob...

Страница 13: ...13433 NFPC 4 NFPC 4 208V 1PH 208V 3PH 15 15 012842 012842 1 1 006950 013432 NFPC 4 NFPC 4 240V 1PH 240V 3PH 15 15 012843 012843 1 1 006950 013432 NFPC 4 380V 3PH 15 012843 1 013432 NFPC 4 NFPC 4 480V...

Страница 14: ...OM NFPC 14 Wiring Diagrams...

Страница 15: ...OM NFPC 15 Wiring Diagrams...

Страница 16: ...OM NFPC 16 Wiring Diagrams...

Страница 17: ...OM NFPC 17 Wiring Diagrams...

Страница 18: ...OM NFPC 18 Wiring Diagrams...

Страница 19: ...OM NFPC 19 Wiring Diagrams...

Страница 20: ...OM NFPC 20 Wiring Diagrams...

Страница 21: ...OM NFPC 21 Wiring Diagrams...

Страница 22: ...OM NFPC 22 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed by...

Страница 23: ...portal transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenan...

Страница 24: ...1055 Mendell Davis Drive Jackson MS 39212 Telephone 601 372 3903 OM NFPC Revised 3 98 FAX 601 373 9587 Part Number 121009...

Отзывы: