Groen HY-12GF Скачать руководство пользователя страница 15

15

OM-HY-12G/24G

OM-HY-12G/24G

15

Adjust the door latch pin to allow for changes

that might occur as the gasket ages

3. Adjust the door latch pin to allow for changes that

might occur as the gasket ages.

a. Loosen the lock nut at the base of the latch

pin, then turn the latch pin ¼ turn clockwise,

and tighten the lock nut.

b. After adjustment, run the unit to test for further

steam leakage.

c. If there is still leakage, repeat the adjustment.

d. Continue adjusting the pin clockwise until the

door fits tightly enough to prevent leakage.

NOTE:  It is important that the flue outlet be checked

regularly. Debris covering the flue outlet can cause a

potentially hazardous condition. Remove any foreign

material before using this equipment.

Troubleshooting

The Groen Steamer is designed to operate smoothly and efficiently if properly maintained.  However, the

following is a list of checks to make in the event of a problem.  Wiring diagrams are furnished inside the service

panel and at the back of this manual.  If an item on the check list is marked with (

), it means that the work

should be done by a factory-authorized service representative.

SYMPTOM

WHO

WHAT TO CHECK

indicates items which must be performed by an authorized technician.

Pilot will not light

User

a. Are electrical connections made with a ground?

b. Is gas supply connection made?

c. Is pilot ignition switch activated?

d. Is gas valve turned on?

e. Are building fuses or circuit breakers all right?

f.

Are there drafts which might blow out the pilot?

Auth Service Rep

Only

g. Is spark ignition cable connected to pilot module?

Steam generator does not fill with

water.

User

a. Is the ON switch depressed?

b. Is electric supply connected?

c. Is the water supply connected?

d. Low water pressure (below 30 PSI or 210 kPa)?

e. Is the screen at the water connection clogged?

f.

Has the steam generator been delimed? 

Pilot will light, but main burners will

not light.

User

a. Is “ON” swtich depressed?

b. Is water supply connected?

c. Are steamer doors open?

d. Is water screen or filter clogged?

Pilot will light, but no panel lamp

comes on

Call your authorized Groen Service Agency.

Service Light flashes.  (New Models). 

(See Cleaning Section)

User

a. Is the water supply connected?

b. Is water supply hose kinked?

c. Is water screen or filter clogged?

d. Has the steam generator been delimed? (Refer to

Cleaning Section)

Excessive steam escaping from rear

of unit

User

a. Is the water spray hose kinked or obstructed?

Auth Service Rep

Only

b. Is the water spray solenoid connected?

Содержание HY-12GF

Страница 1: ...CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO...

Страница 2: ...CLEANING THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARN...

Страница 3: ...York New York 10018 Z21 30 Installation of Gas Appliances Piping Z223 1 1984 National Fuel Gas Code NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 54 Instal...

Страница 4: ...Newer model HY 12GF and HY 24GF steamers manufactured since November 1999 are equipped with fully electronic controls and a button activated pre programmed CLEAN cycle These units are readily identifi...

Страница 5: ...ot specifically designed to work with Groen steamers and combination ovens 2 A well maintained water treatment system and a regular cartridge replacement schedule is essential 3 Using a Groen PureStee...

Страница 6: ...AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK HY 12GF UTILITY CONNECTIONS 1 Electrical connection 13 mm conduit fitting 2 Cold water supply connection 19 mm hose 3 Drain connection 2 64 mm hos...

Страница 7: ...AL OR MECHANICAL CHANGE IN THE UNIT WITHOUT PRIOR APPROVAL FROM THE GROEN FOOD SERVICE ENGINEERING DEPARTMENT MAY VOID ALL WARRANTIES 1 Electrical Supply Connection Provide 115 VAC 60 HZ 1 PH 15 AMP s...

Страница 8: ...roper installation of drain lines from the drain box and for tabletop installation without a drain box CAUTION DO NOT CONNECT THE HOSE DIRECTLY TO A BUILDING DRAIN BLOCKING THE DRAIN COULD BE DANGEROU...

Страница 9: ...Once the pilot burner flame has been established the green light on the pilot switch or electrical panel new models is on press the ON switch for the desired steamer cavity The steam generator will fi...

Страница 10: ...shuts it off The READY indicator light shows that the steam generator is at standby temperature and the cavity is hot enough to begin steaming The DELIME indicator light is lit when the unit is operat...

Страница 11: ...l ON Position Power ON OFF Button Power Indicator Light Ready Indicator Light Service Indicator Light Clean Cycle Button High Temp Indicator Light Deliming Port Delime In progress Indicator Light Manu...

Страница 12: ...ing steps If you want to steam the food for a certain length of time set the timer for that period The timer will automatically run the steamer for the set time and then turn it off A red light will c...

Страница 13: ...aces for bacteria to grow Do not use steel wool which may leave particles imbedded in the surface and cause corrosion and pitting WARNING BEFORE CLEANING THE OUTSIDE OF THE STEAMER DISCONNECT THE ELEC...

Страница 14: ...r DONE light will flash and beeper will beep STEP 6 Press ON OFF to turn steamer off Let cavity cool for 5 minutes or longer Open door wipe out inside of cavity and wipe door gasket Close door STEP 7...

Страница 15: ...WHAT TO CHECK indicates items which must be performed by an authorized technician Pilot will not light User a Are electrical connections made with a ground b Is gas supply connection made c Is pilot...

Страница 16: ...16 OM HY 12G 24G OM HY 12G 24G 16 Parts List...

Страница 17: ...126011 8 Timer Steamer 60 Hz 096826 26 Capacitor 7 5 F 106271 44 Hose Steam Inlet 1 2 dia 5 3 8 l 106581 9 Knob Timer 123100 27 Probe Water Short 141285 45 Hose Steam Inlet 1 1 2 I D x 13 106578 10 S...

Страница 18: ...18 OM HY 12G 24G OM HY 12G 24G 18 Schematic Wiring Diagrams...

Страница 19: ...19 OM HY 12G 24G OM HY 12G 24G 19 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Страница 20: ...bor and portal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not...

Страница 21: ...NOTES...

Страница 22: ...NOTES...

Страница 23: ......

Страница 24: ...OM HY 12G 24G Part Number 142253 Rev C 1055 Mendell Davis Drive Jackson MS 39272 Telephone 601 372 3903 Fax 601 373 9587 www groen com...

Отзывы: