OM-HFP
Installation
The Braising Pan should be installed in a
ventilated room for efficient performance. Items
which might obstruct or restrict the flow of air for
combustion and ventilation must be removed.
The area directly around the braising pan must
be cleared of all combustible material.
WARNING
INSTALLATION OF THE BRAISING PAN
MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH GAS AND
ELECTRICITY. IMPROPER INSTALLATIN
CAN RESULT IN INJURY TO PERSONNEL
AND/OR DAMAGE TO EQUIPMENT.
1. Installation on combustible floors is
allowed, with a minimum clearance to
combustible and noncombustible
construction of six inches at the rear,
and zero inches at the sides. will be
attached, following the accompanying
instructions regarding anchoring and
location.
b. Stub in the electrical service and
service and gas supply line so that
they will be aligned with the control
console on the left side of the pan
once the pan is mounted.
c. Mount the pan on the protruding studs
of the chair carrier.
Make
sure
the
bottom of the pan body is level,
before you proceed to the next step.
To prevent sanitation problems, seal
the junction between pan and the wall
with an NSF-approved material such
as "Silastic"
5. Complete the piping to the gas service
by using % inch IPS pipe or approved
equivalent.
Install the unit under a vent hood.
3. For Open Leg Models (HFP/1, HFP/1E,
HFP/2, HFP/2E):
Level the unit by adjusting the bullet
feet or floor flanges on the legs. Be sure
the tilting mechanism has been turned
all the way to the horizontal position.
Check levelness with a spirit level set
on the bottom of the pan body. Anchor
the rear legs securely to the floor if floor
flanges are ordered or required.
4. Wall-Mounted Models (MW/HFP/1,
MW/HFP/1E, MW/HFP/2, MW/HFP/2E
a. Install the provided "chair carrier"
frame in the wall to which the pan
6. For a unit on casters, complete
connection to the gas supply with
connectors that comply with the
standard for Connectors for Moveable
Gas Appliances, ANSI Z21,69a-latest
edition. Restrain movement of the unit
by attaching a cable or chain to the
eyelet (provided at the back of the
frame) and anchoring the cable or chain
to the wall or floor. Make the length and
location of the cable such that the unit
cannot pull on the gas connection while
the cable is connected.
7. The gas connection must be made with a
quick disconnect device compliant with
ANSI Z21.41b - latest edition.
Typical Multi-Unit Chair Carrier
WARNING:
THIS UNIT IS FOR COMMERCIAL USE.
NEVER USE HOME OR RESIDENTIAL
GRADE GAS CONNECTIONS. THEY DO
NOT MEET GAS CODES AND COULD BE
HAZARDOUS.
2.
7