background image

10 OM-DEES

Operation

same process above.

h.  HIGH TEMP button – Used to set operating temperature of the kettle 

at a preset high intensity (default = 7).  Can be pressed at any time 

during operation of the unit to change the set temperature to the 

preset value except when there is an active TIMER enabled.

i. 

TIMER button - once the appropriate set temperature is selected 

using the HIGH TEMP, MANUAL or LOW TEMP buttons; a countdown 

timer can be set to remind the user when the cooking process is 

completed.

1.  Range – 1 minute to 10 hours

2.  When the timer expires: 

a. 

the set temperature will automatically change to the LOW 

TEMP setting and will continue at this setting until the 

user changes the temperature via MANUAL or HIGH TEMP 

buttons

b.  An audible alarm will notify the user that attention is 

required, the alarm will continue to sound until the user 

presses the TIMER button.   

3.  An active timer can be cancelled by pressing and holding the 

TIMER button for 5 secs

4.  Set temp can be changed during an active timer by pressing 

the MANUAL button and adjusting the set temp using the 

Temperature knob and display.

5.  HIGH TEMP and LOW TEMP presets cannot be used to change 

the setpoint once a TIMER has started.

j. 

READY alarm – The control will sound 3 beeps when the unit has 

reached within 20 degrees of set point during pre-heat and when a 

higher set temperature is selected.

k. 

Crank tilt - a handle controls the worm and gear mechanism that 

smoothly tilts the kettle body and holds it in the desired position.

B.  Operating Instructions

1.  To Start kettle with Classic controls

a. 

 EVERY DAY make sure the jacket water level is above the mid-point 

of the round sight glass.  If the level is too low, see “Jacket Filling” 

and “Water Treatment” on page 16 of this manual.

b.  Check the pressure gauge. If the gauge does not show 20-30 inches 

of vacuum (that is, a reading of 20 to 30 below 0), see “Jacket Filling” 

and “Water Treatment” on page 16 of this manual.

c. 

Turn on the electrical power to the unit.

d.  Turn on the main power switch on the control face.

e. 

Turn the temperature knob to the desired setting.  The heating 

indicator light indicates that the kettle is heating, and cycling of 

the on and off indicates that the kettle is being held at the set 

temperature.  Once in each cycle the contactors in the support 

housing will make a clicking sound.  This is normal.

2.  To Start kettle with Advanced controls

a. 

 EVERY DAY make sure the jacket water level is above the mid-point 

of the round sight glass.  If the level is too low, see “Jacket Filling” 

and “Water Treatment” on page 16 of this manual.

b.  Check the pressure gauge. If the gauge does not show 20-30 inches 

of vacuum (that is, a reading of 20 to 30 below 0), see “Jacket Filling” 

and “Water Treatment” on page 16 of this manual.

Содержание DEES-40

Страница 1: ...ility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of da...

Страница 2: ...OOKING HOLDING OR CLEANING KEEP LIQUIDS A MINIMUM OF 2 3 5 8 cm BELOW THE KETTLE BODY RIM TO ALLOW CLEARANCE FOR STIRRING BOILING AND SAFE PRODUCT TRANSFER WARNING TAKE SPECIAL CARE TO AVOID CONTACT W...

Страница 3: ...T NEVER USE A HIGH PRESSURE HOSE TO CLEAN KETTLE SURFACES CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOULD BE TAKEN WEAR RUBBER GLOVES GOGGLES OR FAC...

Страница 4: ...DE SALES CENTER ECOLAB Inc 370 Wabasha St Pau Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National El...

Страница 5: ...irless operation of the steam jacket permits uniform efficient heating at temperatures as low as 150 F and as high as 298 F In addition to the electronic temperature control the unit has a tilt cut of...

Страница 6: ...oroughly inspect the unit for concealed damage Report any shipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this i...

Страница 7: ...ce at the rear of the support housing with one inch conduit making a watertight connection with the incoming lines Observe local codes and or the National Electrical Code in compliance with ANSI NFPA...

Страница 8: ...of this manual begin heating the water at the highest thermostat setting The heating indicator light should come on immediately and heating should continue until the water boils 7 To shut down the uni...

Страница 9: ...ng elements and will cycle on and off once the unit reaches set temperature If the unit is tilted the heating elements will be disabled and the light will turn off until the unit is returned to the co...

Страница 10: ...d within 20 degrees of set point during pre heat and when a higher set temperature is selected k Crank tilt a handle controls the worm and gear mechanism that smoothly tilts the kettle body and holds...

Страница 11: ...apron When putting a lift off cover on the kettle position it on top of kettle rim with its flat edge facing the pouring lip When removing the lift off cover 1 Firmly grasp the handle 2 Lift rear edge...

Страница 12: ...uct lift straight up ensuring basket bottoms clear the kettle rim and pouring lip Wear protective oven mitts and protective apron 6 Allow hot water to fully drain from product before moving basket awa...

Страница 13: ...erature This is why the heating indicator light cycles on and off during normal operation Every time the kettle is tilted the tilt cut off switch interrupts the power supply to the heaters so that the...

Страница 14: ...the marks on the gauge glass If the level is low see Jacket Filling and Water Treatment on page 16 3 Carefully test the pressure relief valve at least twice each month With the kettle operating at 15...

Страница 15: ...e every six months 8 Use a 2 grade LGI lithium grease to add grease through Zerk fittings on gear housing until it flows out of the bearings around the trunnion shaft 9 Place liberal amounts of grease...

Страница 16: ...t or if the vacuum is leaking down contact an authorized service agency to correct the problem C Jacket Filling and Water Treatment The jacket was charged at the factory with the proper amount of trea...

Страница 17: ...up 5 Stir the water continuously while you slowly add water treatment com pound until the water reaches a pH between 10 5 and 11 5 Judge the pH by frequently comparing the test strip color with the co...

Страница 18: ...clean soiled external and internal surfaces Remember to check the sides of the unit and control housing f To remove stuck materials use a brush sponge cloth plastic or rub ber scraper or plastic wool...

Страница 19: ...horoughly i It is recommended that each piece of equipment be sanitized just before use j If there is difficulty removing mineral deposits or a film left by hard water or food residues clean the kettl...

Страница 20: ...ow water cutoff X Kettle will not heat but heating indicator comes on Authorized Service Rep Only a Temperature control calibration and offsets X b Heater elements with ohmmeter for ground short or op...

Страница 21: ...OM DEES 21 Parts List For Classic Advanced Control Models...

Страница 22: ...22 OM DEES Parts List For Classic Advanced Control Models...

Страница 23: ...TER LEVEL BOARD 122192 19 PRESSURE SWITCH 096963 20 CONTROL CLASSIC CONTROL ADVANCED 174843 174837 21 WATER LEVEL PROBE 070178 22 ELEMENT 208V 9 95KW ELEMENT 240V 8KW ELEMENT 480V 8KW 005977 005974 00...

Страница 24: ...24 OM DEES Wiring Diagram For Classic Control Models...

Страница 25: ...OM DEES 25 Wiring Diagram For Advanced Control Models...

Страница 26: ...26 OM DEES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Service Performed Performed By...

Страница 27: ......

Страница 28: ...REV C 07 17 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2017 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Отзывы: