10 OM-DEES
Operation
same process above.
h. HIGH TEMP button – Used to set operating temperature of the kettle
at a preset high intensity (default = 7). Can be pressed at any time
during operation of the unit to change the set temperature to the
preset value except when there is an active TIMER enabled.
i.
TIMER button - once the appropriate set temperature is selected
using the HIGH TEMP, MANUAL or LOW TEMP buttons; a countdown
timer can be set to remind the user when the cooking process is
completed.
1. Range – 1 minute to 10 hours
2. When the timer expires:
a.
the set temperature will automatically change to the LOW
TEMP setting and will continue at this setting until the
user changes the temperature via MANUAL or HIGH TEMP
buttons
b. An audible alarm will notify the user that attention is
required, the alarm will continue to sound until the user
presses the TIMER button.
3. An active timer can be cancelled by pressing and holding the
TIMER button for 5 secs
4. Set temp can be changed during an active timer by pressing
the MANUAL button and adjusting the set temp using the
Temperature knob and display.
5. HIGH TEMP and LOW TEMP presets cannot be used to change
the setpoint once a TIMER has started.
j.
READY alarm – The control will sound 3 beeps when the unit has
reached within 20 degrees of set point during pre-heat and when a
higher set temperature is selected.
k.
Crank tilt - a handle controls the worm and gear mechanism that
smoothly tilts the kettle body and holds it in the desired position.
B. Operating Instructions
1. To Start kettle with Classic controls
a.
EVERY DAY make sure the jacket water level is above the mid-point
of the round sight glass. If the level is too low, see “Jacket Filling”
and “Water Treatment” on page 16 of this manual.
b. Check the pressure gauge. If the gauge does not show 20-30 inches
of vacuum (that is, a reading of 20 to 30 below 0), see “Jacket Filling”
and “Water Treatment” on page 16 of this manual.
c.
Turn on the electrical power to the unit.
d. Turn on the main power switch on the control face.
e.
Turn the temperature knob to the desired setting. The heating
indicator light indicates that the kettle is heating, and cycling of
the on and off indicates that the kettle is being held at the set
temperature. Once in each cycle the contactors in the support
housing will make a clicking sound. This is normal.
2. To Start kettle with Advanced controls
a.
EVERY DAY make sure the jacket water level is above the mid-point
of the round sight glass. If the level is too low, see “Jacket Filling”
and “Water Treatment” on page 16 of this manual.
b. Check the pressure gauge. If the gauge does not show 20-30 inches
of vacuum (that is, a reading of 20 to 30 below 0), see “Jacket Filling”
and “Water Treatment” on page 16 of this manual.
Содержание DEES-40
Страница 21: ...OM DEES 21 Parts List For Classic Advanced Control Models...
Страница 22: ...22 OM DEES Parts List For Classic Advanced Control Models...
Страница 24: ...24 OM DEES Wiring Diagram For Classic Control Models...
Страница 25: ...OM DEES 25 Wiring Diagram For Advanced Control Models...
Страница 27: ......