3.  Cook2Temp™ Control (-GC2T™)  Models 

a.  Lighted Power ON switch located on the control console. Controls main 

power to the unit.

b.  Heating indicator light located on the control console, lights when the 

controller calls for the main gas valve to open and will cycle on and off 
once the unit reaches set temperature. If the unit is tilted, the call for heat 
will be interrupted and the light will turn off until the unit is returned to the 
cooking position.

c.  Set Mode – Allows power to the controller and the pilot to light, but the 

main burners remain off. The pan will heat once the LOW TEMP, MANAUAL 
or HIGH TEMP button is selected.

d.  LOW TEMP Button – Used to set a unit temperature of the pan at a preset 

low temperature (default = 175°F). Can be pressed at any time during 
operation of the unit to change the unit temperature to the preset value 
except when there is an active TIMER or an active Cook2Temp.

e.  MANUAL Button – Enables the user to modify the unit temperature of the 

pan (between 175°F and 425°F) using the temperature knob and display 
(default = 212°F). The operator will press the MANUAL button and then 
select the desired unit temperature using the temperature knob and display. 
Once the desired unit temperature is shown on the display, the user may 
either press the MANUAL button again or wait 5 seconds and the selected 
temperature will be accepted by the controller and locked in. After the 
selected temperature is accepted it may be changed at any time by pressing 
the MANUAL button and resetting the temperature using the same process 
as above except when there is an active AUTO Cook2Temp.

f.  HIGH TEMP Button – Used to set unit temperature of the pan at a preset 

high temperature (default = 425°F). Can be pressed at any time during 
operation of the unit to change the unit temperature to the preset value 
except when there is an active TIMER or an active Cook2Temp.

g.  TIMER Button – Once the appropriate unit temperature is selected using 

the LOW TEMP, MANUAL or HIGH TEMP buttons, a countdown timer can be 
set to remind the user when the cooking process is completed.
1.  Range – 1 minute to 10 hours.
2.  When the timer expires:

a.  The unit temperature will automatically change to the LOW TEMP 

setting and will continue at this setting until the user changes the 
temperature via MANUAL or HIGH TEMP buttons.

b.  An audible alarm will notify the user that attention is required, the 

alarm will continue to sound until the user presses the TIMER button.

3.  An active timer can be cancelled by pressing and holding the TIMER 

button for 5 seconds.

4.  Unit temperature can be changed during an active timer by pressing 

the MANUAL button and adjusting the unit temperature using the 
temperature knob and display.

5.  LOW TEMP and HIGH TEMP presets cannot be used to change the unit 

temperature once a TIMER has been enabled.

6.  AUTO C2T and MANUAL C2T cannot be used once a timer has been 

enabled. The timer must first be cancelled and then AUTO C2T or 
MANUAL C2T can be enabled.

h.  Ready alarm – The control will sound 3 beeps when the unit has reached 

within 20 degrees of set point during pre-heat and when a higher unit 
temperature is selected.

i.  AUTO C2T Button – Enables the user to select a set product temperature 

(between 100°F and 230°F) using the temperature knob and display. 
The operator will press the AUTO C2T button and then select the set 
product temperature using the temperature knob and display. Once the 
set product temperature is shown on the display, the user may either 
press the AUTO C2T button again or wait 5 seconds and the selected 
temperature will be accepted by the controller and locked in. The unit 

temperature is automatically set 100°F above the set product temperature 
and cannot be changed at any time during an active AUTO C2T. After the 
set product temperature is accepted it may be changed at any time by first 
cancelling AUTO C2T and then using the same process as above to reset 
the temperature.
1.  After the set product temperature is accepted by the controller and 

locked in. The unit will begin to heat and the display will scroll the 
actual product temperature followed by the set product temperature. 
This display will continue until the cook process has completed.

2.  An active AUTO C2T can be cancelled by pressing and holding the AUTO 

C2T button for 5 seconds and the unit will then return to Set Mode.

3.  LOW TEMP, MANUAL or HIGH TEMP presets cannot be used to change 

the unit temperature once there is an active AUTO C2T. The unit 
temperature is automatically set by the controller.

4.  Once the set product temperature has been reached and held for 20 

seconds consecutively the unit will automatically enable Hold Mode.

j.  MANUAL C2T Button – Enables the user to select a set product 

temperature (between 100°F and 230°F) using the temperature knob and 
display. The operator will press the MANUAL C2T button and then select 
the set product temperature using the temperature knob and display. 
Once the set product temperature is shown on the display, the user may 
either press the MANUAL C2T button again or wait 5 seconds and the 
selected temperature will be accepted by the controller and locked in.  
Once the set product temperature has been accepted the user will be 
prompted to select a unit temperature via the MANUAL button. Once 
the set unit temperature is shown on the display, the user may either 
press the MANUAL C2T button again or wait 5 seconds and the selected 
temperature will be accepted by the controller and locked in. After the set 
product temperature and unit temperature are accepted the set product 
temperature may be changed at any time by first cancelling MANUAL C2T 
and then using the same process as above to reset the temperature.
1.  After the set product temperature and unit temperature are accepted 

by the controller and locked in. The unit will begin to heat and the 
display will scroll the actual product temperature followed by the set 
product temperature. This display will continue until the cook process 
has completed.

2.  An active MANUAL C2T can be cancelled by pressing and holding the 

MANUAL C2T button for 5 seconds and the unit will then return to Set Mode.

3.  Unit temperature can be changed during an active MANUAL C2T by 

pressing the MANUAL button and adjusting the unit temperature using 
the temperature knob and display.

4.  Once the set product temperature has been reached and held for 20 

seconds consecutively the unit will automatically enable Hold Mode.

k.  Hold Mode – Allows the unit to be controlled by the set product temperature 

and core probe.
1.  Hold Mode is automatically enabled once a set product temperature 

has been reached and held for 20 seconds consecutively. 

2.  The display will scroll the actual product temperature followed by the 

hold timer.

3.  If the actual product temperature falls below 142°F.

a.  An audible alarm along with the display flashing the actual 

product temperature will notify the user that attention is required. 

b.  The alarm can be silenced by pressing any button. 
c.  The Alarm will resound every 10 minutes until the product 

temperature returns above 142°F.

4.  If the actual product temperature rises 10°F above the set product 

temperature.
a.  An audible alarm along with the display flashing the actual 

product temperature will notify the user that attention is required. 

b.  The alarm can be silenced pressing any button. 

Содержание BPM-15GA

Страница 1: ...ds The pan body is made from heavy duty stainless steel welded into one solid piece with a polished interior and exterior A pouring lip is welded to the front wall The cooking surface is a stainless s...

Страница 2: ...O NOT HEAT EMPTY PAN FOR MORE THAN 5 MINUTES AT A SETTING HIGHER THAN 300 F WARNING IF THE PAN CONTAINS ITEMS IN HOT LIQUIDS SUCH AS SAUCE OR MELTED FAT THEY CAN SLIDE FORWARD SUDDENLY DURING TILTING...

Страница 3: ...ith a connector that complies with the standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 Restrain movement of the unit by attaching a cable or chain to the eyelet provided at the...

Страница 4: ...eating indicator light is located on the control console it illuminates when the controller calls for the main gas valve to open If the unit is tilted the call for heat will be interrupted and the lig...

Страница 5: ...ds and the selected temperature will be accepted by the controller and locked in The unit temperature is automatically set 100 F above the set product temperature and cannot be changed at any time dur...

Страница 6: ...user that attention is required Simply plug the core probe back into the receptacle and the cook process or Hold Mode will continue e While the core probe is not in use ensure the sealing cap is prop...

Страница 7: ...ion NOTICE It is recommended that an instant read thermometer be used to check the internal temperature throughout the cooking process and after the cooking process has been completed to ensure the fo...

Страница 8: ...be polished with a recognized stainless steel cleaner 8 If the equipment needs to be sanitized use a sanitizing solution equivalent to one that supplies 100 parts per million available chlorine Obtain...

Страница 9: ...least 3 5 W C 8 7millibars X d For gas at the pilot If it is not flowing 1 Check the pilot gas line for kinks and obstructions X 2 Clean orifice if necessary X 3 Check solenoid operation pilot valve o...

Страница 10: ...ne model to natural gas for other elevations above 2000 feet contact the factory BURNER ORIFICE QUANTITY CHART Model 15 Gallon 30 Gallon 40 Gallon BPM or BPP 7 11 15 Parts List FUEL GAS CONVERSION CAL...

Страница 11: ...7 4 DOME NUTS 1 4 20 090567 8 2 SCREW TRUSS HEAD 10 32 X 3 8 004173 Parts List COVER COUNTERBALANCE ASSEMBLIES CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Parts List MANUAL TILT ASSEMBLY CALL FAC...

Страница 12: ...X 10 005558 13 1 REAR RADIATION HEAT SHIELD 146145 14 1 IGNITION MODULE COVER 146146 15 2 SCREW ROUND HEAD MACHINE 018384 16 1 NIPPLE 1 2 NPT X 15 048570 17 1 VALVE GAS MANUAL SHUT OFF 1 2 098458 18...

Страница 13: ...ER TUBE 30 GAL 144847 5 15 BURNER TUBE 40 GAL 144847 6 21 NUT KEPS 1 4 20 012940 7 1 IGNITION TUBE 15 GAL 155722 7 1 IGNITION TUBE 30 GAL 145957 7 1 IGNITION TUBE 40 GAL 145912 8 1 IGNITION TUBE ORIFI...

Страница 14: ...CE 50VA 208 230 460V 148899 26 1 TERMINAL BLOCK 003887 27 1 SWITCH SEAL 144963 28 1 COVER TERMINAL BLOCK BOX 175043 29 1 TERMINAL BLOCK BOX 175042 30A 1 CONTROL CLASSIC NOT SHOWN 174841 30B 1 CONTROL...

Страница 15: ...012614 9 1 MOTOR BRACKET 146114 10 1 REAR MOTOR BRACKET 146117 11a 1 FUSE HOLDER MOTOR 077840 11b 1 FUSE MOTOR LP CC 5 120VAC 5A 144855 11b 1 FUSE MOTOR LP CC 2 1 2 230VAC 2 1 2A 144856 11c 1 RECTIFIE...

Страница 16: ...16 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram CLASSIC CONTROL MANUAL TILT FOR GC MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 17: ...17 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram CLASSIC CONTROL POWER TILT FOR GC MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 18: ...18 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram ADVANCED CONTROL MANUAL TILT FOR GA MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 19: ...19 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram ADVANCED CONTROL POWER TILT FOR GA MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 20: ...20 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram COOK2TEMP CONTROL MANUAL TILT FOR GC2T MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 21: ...21 OM BPM 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Wiring Diagram COOK2TEMP CONTROL POWER TILT FOR GC2T MODELS CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 22: ...M 15 30 40G C A C2T BPP 30 40G C A C2T Domestic Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Perfo...

Отзывы: