OM-AH

SYMPTOM

WHO

WHAT TO CHECK

;

;

;

;

 indicates items which must be performed by an authorized technician.

15

Safety Valve

 

pops open

User

a. For air in the jacket.  See “Jacket Vacuum” in the Maintenance section.

b. Thermostat dial setting.

Auth

Service

Rep Only

c. For defective thermostat.  The thermostat should click when the dial is

rotated to settings above and below the temperature of the kettle.  If

defective, replace.

;

d. For defective safety valve.  If the valve pops at pressures below 29 PSI,

replace.

;

Burners will not light.

User

a. That the main gas supply valve is open.  (handle is in line with the gas

pipe).

b. Gas supply to the building.

Auth

Service

Rep Only

d. Thermostat operation.  The thermostat should click when the dial is

rotated to settings above and below the temperature of the kettle.

;

System does not produce a spark Auth

Service

Rep Only

a. AC voltage between terminals on secondary side of transformer with

unit power turned on.  If it is not  24 Volt, replace the transformer 

;

b. That the high tension cable is firmly attached and in good condition.  If

cracked or brittle, replace.

;

c. Pilot burner ceramic insulatorfor crack or break.

;

d. Pilot spark gap.  Regap.

;

Spark is present but the pilot will

not light.

Auth

Service

Rep Only

a. That the pilot valve is securely connected to terminals.

;

b. For 24 VAC at terminals PV and PV/MV.  If 24V is not present, replace

the ignition control module.

;

b. That gas pressure is at least 3.5" W.C.(8.7818 

:

b).

;

c. For gas at the pilot.  If it is not flowing:

(1) Check the pilot gas line for kinks and obstructions.

;

 

(2) Clean orifice, if necessary.

;

(3) Check magnetic operator for pilot valve on gas valve.  Repair or

replace as necessary.

;

d. That the pilot spark gap is located in the pilot gas stream.  If not, adjust

or replace the pilot burner.

;

e. For drafts.  Shield the pilot burner, if necessary.

;

Pilot lights, but main burner will

not come on  and spark does not

stay on.

Auth

Service

Rep Only

a. For 24 V between terminals MV and PV/MV while pilot is burning.  If

24V is not present, replace the ignition control module.

;

b. That gas pressure is at least 3.5" W.C.(8.7818 

:

b).

;

c. Electrical connections of the main valve to terminals, to assure that they

are securely attached.  Check magnetic operator for main valve on gas

valve.  Repair or replace as necessary.

;

Pilot lights, but main burner will

not come on, the spark stays on.   

   

Auth

Service

Rep Only

a. Check for bad burner ground.  If necessary, repair with high

temperature wire.

;

b. Pilot burner ceramic insulator for cracks.

;

c. That cable is not grounded out.  If it is, correct the ground-out condition

or replace cable.

;

d. For proper gas pressure.

;

e. Clean pilot assembly, or replace if necessary.

;

f. Tighten all mechanical and electrical connections.

;

g. If the pilot flame is weak, increase pilot orifice size.

;

h. Replace ignition control module.

;

Main burner comes on but will not

stay on.

Auth

Service

Rep Only

a. Check burner ground for bad wire or connection.  Replace if necessary

with high temperature wire.

;

b. Check for low gas supply pressure.  If necessary, replace ignition

control module.

;

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Содержание AH/1

Страница 1: ...CINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS...

Страница 2: ...BRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING CAREFULLY READ WARNINGS AND FOLLOW DIRECTIONS ON CLEANER LABELS NOTICE NEVER LEAVE A SANITIZER IN...

Страница 3: ...hio 44131 ANSI Z83 11 NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michigan 48106 NSF ANSI 4 AMERICAN NAT L STANDARDS INST INC 1430 Broadway New York New York 10018 Z223 1 1984 National F...

Страница 4: ...what is happening inside the unit These are a Water level sight glass Indicates whether there is enough water in the steam jacket b Pressure vacuum gauge Shows steam pressure and whether too much air...

Страница 5: ...damage Open the container and check the unit for hidden damage Report shipping damage or shipment errors to the delivery agent Write down the model number serial number and installation date for your...

Страница 6: ...above Securely fasten the screw to attach draft directly Do not change the diverter in any way WARNING DO NOT ATTACH THE UNIT TO A TYPE B VENT FAILURE COULD RESULT IN FIRE OR PROPERTY DAMAGE Install...

Страница 7: ...ng system at test pressures equal to or less than 1 2 PSIG 3 48 kPa 16 Check the following points to confirm that your AH kettle has been installed properly electrical or gas type change must be appro...

Страница 8: ...TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE SAFETY VALVE 1 To Start Kettle a CHECK THE WATER LEVEL IN THE JACKET EVERY DAY The level shoul...

Страница 9: ...TIRRING OR TRANSFERRING PRODUCT TO ANOTHER CONTAINER CAUTION DO NOT OVERFILL THE KETTLE WHEN COOKING HOLDING OR CLEANING KEEP LIQUIDS 2 3 5 8 cm BELOW THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BO...

Страница 10: ...urn off the power switch Check the gas supply valves and wait five minutes before trying again by switching power on If you cannot establish a pilot flame in four tries close all valves turn off the p...

Страница 11: ...CONTACT CAN CAUSE CORROSION c Prepare a solution of the detergent cleaning compound as instructed by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to cle...

Страница 12: ...as Groen De limer De Scaler Part Number 114800 Rinse and drain the unit thoroughly before further use m If especially difficult cleaning problems persist contact your cleaning product supplier for as...

Страница 13: ...ng a will screwdriver or other implement to pull the ring help you avoid contact with the steam 3 Jacket Filling Every day before you turn on the unit make sure the water level is approximately in the...

Страница 14: ...s and compound are used in the future However it is best to check the pH each time treated water is prepared Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if proper...

Страница 15: ...is not flowing 1 Check the pilot gas line for kinks and obstructions 2 Clean orifice if necessary 3 Check magnetic operator for pilot valve on gas valve Repair or replace as necessary d That the pilo...

Страница 16: ...OM AH 16 Parts List AH 1E PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 17: ...T x Close 008877 Screw Sheet Metal pan hd 12 x 1 2 lg 008769 Valve Gate 1 2 NPT 004180 Bracket faucet Mounting 16 Ga x 4 3 4 009054 Label Warning 098171 Diverter Draft 6 AH 1E 20 40 012474 Wiring Diag...

Страница 18: ...OM AH 18 Parts List AH 1E 40 PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 19: ...281 Orifice Prop Higher Elev 000403 9 Bracket Pilot Burner Mounting 123824 11 Bracket Pilot Burner Mounting 123824 10 Screw 10 24 x 3 8 lg Round Head 006009 12 Screw 10 24 x 3 8 lg Round Head 006009 1...

Страница 20: ...mbly Front Panel Components Assembly Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description and number quantity and where applicable voltag...

Страница 21: ...Screw 10 32 x 3 8 long 069773 12 Sight Tube 5 8 Dia x 4 3 4 long 008742 Electrical Panel Assembly 123823 13 Fittings Sight Glass Assembly 002845 1 Water Level Control 24V 122192 Front Panel Component...

Страница 22: ...OM AH 22 Electrical Schematic PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Страница 23: ...tion ___________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order No __________________________ For Service Call _____...

Страница 24: ...from date of shipment from Groen IV This warranty does not cover boiler maintenance calibration periodic adjustments as specified in operating instructions or manuals and consumable parts such as scra...

Отзывы: