Maintenance

Marine growth and debris will impede paddlewheel 

operation and may trigger false alerts.  clean all flow  

sensor paddlewheels monthly.  First, close the seacock.  

the sensor can be removed by grasping the pull-ring and 

turning it 90-degrees counter-clockwise – then pull straight 

out.  lubricate the o-rings (Groco #2-120) with silicon or 

teflon® based grease.  Do not use petroleum based grease.

TROUBLESHOOTING

INDICATION  

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION

During calibration, 

calibration 

there is no flow 

check pump, strainer

2 beeps, then solid leD 

not successful 

 

seacock, and hoses

  

 

cables in wrong jack 

check Figure-2

Audible Alert and blinking 

Flow reduction 

Debris on sensor 

clean Sensor

leD during operation 

 

clogged Strainer 

clean Strainer 

  

 

Damaged Pump impeller 

replace impeller

  

 

Failed Pump Motor 

replace Motor

  

 

Partially closed Seacock 

open Seacock

  

 

Kinked hose 

replace hose

  

 

 

 

Alerts flashing and beeping 

 

SSA not calibrated 

calibrate system

no leD flash when consumer  no power 

blown fuse 

replace fuse

is on 

 

Power cord disconnected 

connect power cord

  

 

no self-test routine 

no power 

blown fuse 

replace fuse

  

 

Power cord disconnected 

connect power cord