Maintenance
Marine growth and debris will impede paddlewheel
operation and may trigger false alerts. clean all flow
sensor paddlewheels monthly. First, close the seacock.
the sensor can be removed by grasping the pull-ring and
turning it 90-degrees counter-clockwise – then pull straight
out. lubricate the o-rings (Groco #2-120) with silicon or
teflon® based grease. Do not use petroleum based grease.
TROUBLESHOOTING
INDICATION
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
During calibration,
calibration
there is no flow
check pump, strainer
2 beeps, then solid leD
not successful
seacock, and hoses
cables in wrong jack
check Figure-2
Audible Alert and blinking
Flow reduction
Debris on sensor
clean Sensor
leD during operation
clogged Strainer
clean Strainer
Damaged Pump impeller
replace impeller
Failed Pump Motor
replace Motor
Partially closed Seacock
open Seacock
Kinked hose
replace hose
Alerts flashing and beeping
SSA not calibrated
calibrate system
no leD flash when consumer no power
blown fuse
replace fuse
is on
Power cord disconnected
connect power cord
no self-test routine
no power
blown fuse
replace fuse
Power cord disconnected
connect power cord