![Grizzly Vertical Mill G0667X Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/grizzly/vertical-mill-g0667x/vertical-mill-g0667x_owners-manual_2267346042.webp)
-40-
g0667X high precision Vs Vertical Mill
Always use non-flammable water based
coolant to avoid explosions when the fluid
comes in contact with hot metal chips from
the milling operation. For the best protection
and use, always follow the coolant manufac-
turer's recommendations for coolant/water
ratios.
NOTICE
Running the coolant pump without adequate
coolant in the reservoir may permanently
damage the coolant system on your mill.
This action is considered abuse and is not
covered by the warranty.
3. if the level of coolant is more than 2" below
the top of the reservoir, add more non-flam-
mable water-based coolant to fill the tank.
4. replace the reservoir screen making sure the
fluid return hose is secured in position.
The coolant reservoir on this mill is designed
to store only coolant. During storage some
fluids grow dangerous microbes, or, due
to the collection of toxic metal chips in the
fluid, the fluid can become a potent and
extremely poisonous solution to humans
and animals.
use the correct personal protection equip-
ment when handling coolant to prevent
infections and poisoning.
Follow Federal, State, and the coolant manu-
facturer's requirements to properly dispose
of used coolant.
Changing Coolant
Tools Needed
Qty
hex Wrench 3, 5, 10mm ...........................1 Each
Catch pan .......................................................... 1
To change coolant:
1. disConnECt thE Mill FroM poWEr!
2. place a catch pan under the reservoir drain
plug at the rear of the column (see
Figure
58), remove the plug, and allow the coolant
to completely drain.
Figure 58. Coolant reservoir pump and drain
plug.
drain plug
pump
3. put on personal protective equipment and
remove the pump access panel on the rear
of the column.
4. remove the two pump mounting cap screws
and move the pump out of the way.
5. Clean any debris or sludge from the reservoir
and from around the base of the pump.
6. replace the pump, access panel, and drain
plug.
7. remove the reservoir screen on the base,
fill the reservoir with non-flammable water-
based coolant, then replace the screen.