![Grizzly Vertical Mill G0667X Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/grizzly/vertical-mill-g0667x/vertical-mill-g0667x_owners-manual_2267346041.webp)
g0667X high precision Vs Vertical Mill
-39-
Coolant Reservoir
Coolant is a potent and
extremely
poisonous
solution to humans and
animals. use personal
protective equipment
when handling coolant
to prevent infections or
poisoning.
A small amount of coolant is lost during normal
operation. Check the coolant reservoir regularly
and fill it if necessary.
the Model g0667X coolant reservoir holds
approximately 7 gallons (26 liters) of fluid. We rec-
ommend changing this fluid every three months or
sooner if it develops an unpleasant odor.
Checking Coolant Level
Tools Needed
Qty
hex Wrench 3mm .............................................. 1
To check the coolant level:
1. disConnECt thE Mill FroM poWEr!
2. Clean away debris and grime from the res-
ervoir screen on the base of the mill, then
remove it to inspect the level of coolant (see
Figure 57).
Figure 57. reservoir screen on the base.
reservoir screen
Power Feed Gearing
Lubricant
Frequency
Qty
Multi-purpose
gear grease
Every 3
Months
thin Coat
remove the longitudinal ball handle, then remove
the slotted flat washers from the leadscrew. slide
the graduated dial assembly to the end of the
leadscrew, taking care not to misplace the keys
shown in
Figure 56. Apply a thin coat of general
purpose light grease to the drive gear and brass
gear, then reinstall the parts in reverse order.
Figure 56. power feed gearing.
drive gear
Brass gear
Keys