-14-
G3102/G3103 Vertical Mill
220V Conversion
To operate your mill with 220V power, you must: 1)
replace the 110V power ON/OFF switch with the
included 220V switch, 2) re-wire the motor, 3) re-
wire the transformer, and 4) install a NEMA 6-15
plug and receptacle.
Refer to
Page 44 for the full 220V Conversion
Wiring Diagram.
You MUST disconnect the
mill from the power source
before beginning any of
the following 220V conver-
sion procedures to avoid
serious personal injury or
death by electrocution.
Replacing the Power Switch
Record the wire connections on the 110V switch
before you remove it, then replace it with the
included 220V power switch and make the same
wire connections.
Re-Wiring the Motor
1. Remove the cover of the motor wiring junc-
tion box.
2. Re-configure the two metal terminal jumpers
so that terminals
Z2 and U2 are connected
and
U2 and V1 are connected, as shown in
Figure 3.
2
11
12
3
1
Ground
Capacitor
150M 250V
Capacitor
20M 450V
4
Z2
U2
V2
U1
V1
Z1
Figure 3. Motor configured for 220V operation.
3. Remove the wire from the Z2 terminal and
terminate it with a wire cap and electrical tape
(see
Figure 3), then re-install the wiring junc-
tion box cover.
Re-Wiring the Transformer
Remove the electrical panel access cover on the
rear of the column, then move the wire from the
115V terminal on the transformer to the 230V ter-
minal, as shown in
Figure 4.
230
115
0
0
24
N
N
Transformer
7
8
5
6
9
1
2
4
10
3
Figure 4. Electrical panel transformer configured
for 220V operation.
Covers, guards, and safety devices on
this machine are provided for your safety.
Always keep them secured in place before
connecting the machine to power to avoid
serious personal injury.
Содержание G3102