Model G1163/G1163P (Mfg. Since 9/12)
-21-
Troubleshooting
Motor & Electrical
Symptom
possible Cause
possible Solution
Machine does
not start or a
breaker trips.
1. Switch disabling key removed.
2. Wall fuse/circuit breaker is blown/tripped.
3. power supply switched
OFF or is at fault.
4. Wiring is open/has high resistance.
5. Motor oN/oFF switch is at fault.
6. Motor is at fault.
1. install disabling key.
2. Ensure circuit size is suitable for this machine;
replace weak breaker.
3. Ensure power supply is switched
ON; ensure
power supply has the correct voltage.
4. Check for broken wires or disconnected/
corroded connections, and repair/replace as
necessary.
5. Replace faulty oN/oFF switch.
6. test/repair/replace.
Machine has
vibration
or
noisy operation.
1. Motor or component is loose.
2. Motor mount loose/broken.
3. Machine is incorrectly mounted or sits
unevenly.
4. Motor fan is rubbing on fan cover.
5. Motor bearings are at fault.
1. inspect/replace stripped or damaged bolts/
nuts, and re-tighten with thread locking fluid.
2. tighten/replace.
3. tighten/replace mounting hardware; chock
casters if mobile.
4. Replace dented fan cover; replace loose/
damaged fan.
5. test by rotating shaft; rotational grinding/loose
shaft requires bearing replacement.
SECTION 7: SERvICE
Review the troubleshooting and procedures in this section if a problem develops with your machine. If you
need replacement parts or additional help with a procedure, call our Technical Support at (570) 546-9663.
Note: Please gather the serial number and manufacture date of your machine before calling.