-16-
g1028z/g1029z dust Collector
10. slip the bottom plastic collection bag over the
bottom edge of the collector and tighten the
clamp on the tightest notch possible.
Note:
DO NOT force the clamp, choose the
next notch over, then clamp in place.
11. press the “y” inlet onto the inlet cover flange,
as shown in
figure 12. the inlet is secured
to the collector body by a press-on fit.
figure 12. installing "y" inlet.
Test Run
once the assembly is complete, test run your
machine to make sure it runs properly.
if, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the
Troubleshooting on page 29.
if you still cannot remedy a problem, contact our
tech support at (570) 546-9663 for assistance.
To test run the machine:
1. make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is setup properly.
2. make sure all tools and objects used during
setup are cleared away from the machine..
3. Connect the machine to the power source.
4. turn the machine
ON
.
5. listen to and watch for abnormal noises or
actions. the machine should run smoothly
with little or no vibration or rubbing noises.
— strange or unusual noises should be inves-
tigated and corrected before operating the
machine further. always disconnect the
machine from power when investigating or
correcting potential problems.
6. turn the machine
OFF
.
Do NOT put hands or
small objects near inlet
openings during opera-
tion. Objects sucked into
the inlet will hit the impel-
ler blade. failure to heed
this warning could result
in property damage or
personal injury.