Model G0818 (Mfd. Since 10/16)
-29-
Symptom
Possible Cause
Possible Solution
Loud, repetitious
noise, or excessive
vibration coming
from dust collector
(non-motor related).
1. Dust collector not on a flat surface and
wobbles.
2. Impeller is damaged and unbalanced.
3. Impeller is loose on the motor shaft.
1. Stabilize dust collector; lock casters.
2. Disconnect dust collector from power. Inspect
impeller for dents, bends, or loose fins. Replace
impeller if damaged.
3. Secure impeller; replace motor and impeller as a set
if motor shaft and impeller hub are damaged.
Dust collector does
not adequately
collect dust or chips;
poor performance.
1. Collection drawer or air filter dust tray are
full.
2. Filters are dirty/clogged.
3. Clog in ducting.
4. Leak in ducting/connections.
5. Ducting blocked/restricted.
6. The dust collector is too far away from
the point of suction, or there are too many
sharp bends in the ducting.
7. Dust collector is undersized.
1. Empty collection drawer and dust tray (
Page 25
).
2. Clean filters; replace with new filters if performance
does not improve (
Page 27
).
3. Remove clog.
4. Seal leak.
5. Remove ducting from dust collector inlet and
unblock the restriction.
6. Relocate the dust collector closer to the point of
suction; remove sharp bends in ducting.
7. Install a larger dust collector.