background image

-6-

Model G0711 (Mfg. Since 7/10)

Maintenance

before Every Use
• 

If lubricating manually, place 5 drops of pneu-
matic tool oil in the foot switch air fitting and 
the hammer assembly air fitting.

• 

If  you  are  using  an  in-line  lubricator,  check 
the oil level; refill as needed with pneumatic 
tool oil.

• 

Check all mounting and component hardware 
and fasteners; adjust/tighten as necessary.

• 

Check all air connections; replace leaking or 
defective connections.

Operation

The basic operation of a planishing hammer con-
sists of inserting a piece of sheet metal between 
the hammer and die, then actuating the planishing 
hammer while moving the sheet metal around to 
shape it.

There  are  three  main  variables  that  can  be 

adjusted to alter the results of your work:

• 

Die Radius: Controls the curve of the shaped 
workpiece. Change this by installing dies with 
different radii.

• 

Air  Supply  PSI:  Controls  the  force  of  each 
blow of the hammer. Change this by adjust-
ing the air pressure between 50-100 PSI.

• 

Hammer Speed: Controls how fast and hard 
the  hammer  strikes  the  die  while  the  foot 
switch is pressed. This is measured in BPM's 
(beats per minute). Change this by adjusting 
the  speed  adjustment  knob  on  the  hammer 
assembly.

Figure 13. Die elevation lever.

Die Elevation 

Lever

Die

Hammer

4.  Connect  the  air  pressure  and  adjust  the  air 

supply  PSI  between  50-100,  using  your  air 
regulator.

5.  Adjust  the  hammer  speed,  using  the  speed 

adjustment knob on the hammer assembly.

6.  Insert  the  workpiece  between  the  hammer 

and die, press down on the foot switch, and 
move the workpiece around to shape it.

7.  When  a  shaping  task  is  complete,  remove 

your foot from the pedal to stop the planishing 
hammer.

8.  At the end of the day, or before leaving the 

planishing  hammer  unattended,  disconnect 
the air supply from the foot switch and press 
the  foot  switch  to  release  any  remaining  air 
pressure.

To perform a basic operation with the planish-

ing hammer:

1.  DISCONNECT THE AIR PRESSURE!

2.  Insert the desired die size into the housing.

3.  Adjust  the  height  of  the  die,  using  the  die 

elevation lever (

Figure 13) to accommodate 

the thickness or gauge of your workpiece

Содержание G0711

Страница 1: ...Wear safety glasses and hearing protection while using this tool CRUSHING HAZARD Keep hands clear of ham mer at all times Specifications Control Power Pneumatic Throat Depth 195 8 Hammer Die Opening Usable 3 8 11 4 Maximum Opening Loading Unloading 4 Maximum Workpiece Thickness 5 64 2mm Hammer Speed 875 1350 BPM Operating Air Pressure 50 100 PSI Maximum Air Pressure 100 PSI Air Inlet Size Consumpt...

Страница 2: ...DISCONNECT AIR PRESSURE before servic ing changing accessories or moving to another location Never leave this tool unattended when connected to air SECURE TOOLING Always verify tooling is secure before operation SHARP SURFACES DO NOT place hands near the tooling surfaces when in operation REMOVE ADJUSTING KEYS AND WRENCHES AFTER USE These tools become dangerous projectiles if left on the tool when...

Страница 3: ...and Use 3 8 or 10mm diameter fasteners The length of the bolts screws will depend on the thickness of the workbench The type of fasteners required to install the planishing hammer will depend on how you choose to mount it The two most common options for mounting are the through mount and direct mount methods see Figures 4 5 below After the C frame has been positioned where you want to mount it tra...

Страница 4: ...ammer assembly spring loop to the side and insert the hammer into the coil spring making sure the ring on the ham mer shaft is over the bottom spring loop as shown in Figure 7 3 Insert a die into the die housing as shown in Figure 9 4 Raise the die housing up and insert the pin as shown in Figure 10 to position the die near the hammer The Model G0711 can also be filled with fine sand to reduce vib...

Страница 5: ...than the usual amount of lubrication you will use during maintenance The purpose of this is to load up the pneumatic components when they are new 8 Connect the air supply to the hose coming out of the foot switch see Figure Note There are many different styles of quick connect fittings If the air fitting supplied with the Model G0711 does not fit the style you have on your hose you will need to ma...

Страница 6: ...ure between 50 100 PSI Hammer Speed Controls how fast and hard the hammer strikes the die while the foot switch is pressed This is measured in BPM s beats per minute Change this by adjusting the speed adjustment knob on the hammer assembly Figure 13 Die elevation lever Die Elevation Lever Die Hammer 4 Connect the air pressure and adjust the air supply PSI between 50 100 using your air regulator 5 ...

Страница 7: ... your tools you ll appreciate these High Pressure Oil Cans Each can holds 5 ounces of oil and has a trigger activated high pressure pump T20881 In Line Lubricator 1 4 NPT T20882 Mini Regulator 1 4 NPT G6261 Water Filter 1 4 NPT Install an in line lubricator to apply oil automati cally Install an air regulator right at the tool for precise air control Install this filter in your air sup ply line to...

Страница 8: ...LL PLUG 1 28 2 3 4 5 1 5 2 5 3 6 7 8 9 10 11 12 13 14 15 16 17 18 18 15 18 20 22 23 24 25 26 21 19 S p e c i f i c a t i o n s M O D E L G 0 7 1 1 P L A N I S H I N G H A M M E R W A R N I N G C R U SH IN G H A ZA R D K eep hands cle arofth e ham m erm echanis m at all tim es W A R N IN G EXPLOSION HAZARD Do not exceed 100 PSI when operating this machine WARNING R E A D a n d U N D E R S T A N D i...

Отзывы: