Model G0707 (Mfd. Since 01/21)
-35-
Figure 37. Brush retainer installation.
12. Install and tighten the brush housing retaining
screws.
13. When the brush housings are installed, make
sure to route the brush power wires well away
from the commutator, as shown in
Figure
38, or the commutator will wear into the wire,
causing an electrical short.
Figure 38. Safe power wire routing.
Figure 39. Fan cover installation.
14. Place the fan cover back onto the motor so
the lock tangs lock onto the brush housings,
as shown in
Figure 39.
15. Re-install the motor cover and the dust col-
lector assembly into the canister, and latch
the dust collector in place.
16. Test the dust collector operation.
11. Place the brush housing into the brush seat
on the motor, and place the retainer over the
brush housing so the lock lug drops into the
slot in the brush housing (
Figure 37).
Correct
Incorrect
Lock Tangs