Model g0705 (Mfg. since 09/09)
-13-
4.
remove the screws that secure the brass
contactor mounting plate to the back of the
electrical box, then pull the contactors out
to access the gray tab shown in
figure 7
.
pull outward on the gray tab to release each
contactor from the mounting plate.
5.
install the two 110v contactors from the
Model g0705 110v Conversion Kit in place
of the contactors you removed in
step 4
.
6.
replace the wires you removed in
step 3
to
the corresponding terminals on the 110v con-
tactors. the wiring is the same for 110v and
220v. refer to
section 8: Wiring
starting
on
page 45
for detailed wiring diagrams.
7.
locate the indicator lamp shown in
figures 4
&
5
. disconnect the two wires from its termi-
nals, then remove the lamp.
8.
install the 110v indicator lamp from the
Model g0705 110v Conversion Kit in place
of the lamp you removed in
step 7
.
9.
Connect the wires you removed in
step 7
to
the corresponding terminals on the 110v indi-
cator lamp. the wiring is the same for 110v
and 220v.
figure 7.
Contactor release tab location.
gray tab
Hot
Hot
Ground
6-20 Plug
220
VAC
Ground
Neutral
Hot
Ground
L5-30 Plug
(As Recommended)
PE
V2
V1
U2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
To Electrical Box
Start
Capacitor
150 MFD
250 VAC
Run
Capacitor
20 MFD
450 VAC
110V Terminal
Block Jumper
Position.
(Wire positions
are the same for
110V/220V)
To Electrical Box
Cord Rewired for 110V
Motor 220V
figure 8.
Jumper positions on terminal block.
terminal Block
220v Jumper
location
10.
locate the terminal block located in the motor
junction box, shown in
figure 8
.
Mounting plate
Jumpers Moved
for 110v