Model G0695 (Mfd. Since 01/17)
-33-
NOTICE
Failure to follow the lubrication practices
outlined in this manual could lead to prema-
ture failure of your mill and void the warranty.
One-Shot Oiler
Lubricant
Frequency
Qty
ISO 68 Lubricant or
Equivalent
Every
8 Hours
of Operation
1
Pump
The oil lines running from the one-shot oiler feed
lubrication to the ways of the column (knee),
saddle, and table.
Use the sight glass on the front of the oiler to make
sure it is full, then pull the handle (see
Figure 41)
and release it to send lubricant through the lines.
Figure 41. One-shot oiler.
Oil Line
One-Shot
Pump
Handle
Fill Cap
Quill Gearing
Lubricant
Frequency
Qty
ISO 68 Lubricant or
Equivalent
Every
8 Hours
of Operation
5
Drops
Lift the cap of the oil cup shown in
Figure 42 to
add the lubricant.
Figure 42. Quill gearing oil cup.
Vertical Bevel Gears
Lubricant
Frequency
Qty
NLGI #2 Grease
Every
40 Hours
of Operation
Thin
Coat
Raise the knee up to access the vertical bevel
gears underneath the saddle, then clean and
lubricate the bevel gears shown in
Figure 43.
Figure 43. Vertical bevel gears.