Model G0568/G0569 (Mfd. Since 10/11)
-67-
READ ELECTRICAL SAFETY
ON PAGE 64!
G0569 Wiring Diagram 440V
DISCONNECT SWITCH
(as recommended)
3-PHASE
440 VAC
440V Conversion
= For phase
converter wild
wire (if used)
PWR
ON
OFF
CONTROL PANEL
(viewed from behind)
A
AMP
RESET
96
98
1/2
T1/2
T3/6
NO14
3/4
T2/4
L1/1
L3/5
NO13
L2/3
5/6
95
8
21
22
13
14
21
22
13
14
21
22
13
14
10
12
RESET
NC15
SDE
NC16
Ground
Ground
Ground
LIMIT SWITCH (NC)
FOOT BRAKE
NO
C
SDE
MA-18
POWER
SUPPLY
JUNCTION
BLOCK
3
2
1
MAG SWITCH
2 4
11
12
23
24
Hot
Hot
MOTOR 440V
Ground
U1
V1
U2
V2
U5
V5
W1
W5
W2
2
2
Содержание G0568