4.2 Connection to mains power

The unit can operate with voltage from 100 to 277Vac and with frequency of 50 and 60Hz.

For the connection use main cable in the side of the rear boxl of the fixture and connect as shown below.

4.3 Connection to DMX signal

The DMX signal is to be connected by using a shielded cable designed for devices RS-485.

The signal cable must be connected according to the following table:

GND = Shield

DATA - = Black

DATA + = Red

The projector is fitted with butt connectors and heat shrink tube which allow to perform 

IP67

connections.

To make the connection follow these instructions.

Warning!

• Before connecting the unit, verify that power supplies features are compatible with the unit features.

• The unit must never be installed if not grounded electrically.

• It is suggested to use a magnetothermic switch along the power supply line, as prescribed by in force rules.

• The unit must not be powered up through a dimmer power device.

• Wiring and connection actions are to be performed by a qualified staff.

Live

Ground

Neutral

Brown

Yellow Green

Blue

Main supply

Warning!

Follow the instructions provided along with the connection kit to perform the connections.

Warning!

All data wires must be isolated one from another and from the shield.

The GND of the DMX signal is not to be connected to the electric ground of the unit.

Insert a terminal plug with a 120 Ω resistor connected to DATA- and DATA+ in the last unit.

Warning!

Follow the instructions provided along with the connection kit to perform the connections.

Italiano

19

Содержание RBR250

Страница 1: ...Ruby MC Recessed Manuale di istruzioni Instructions manual...

Страница 2: ...1 5 5 1 DMX functions with DMX MODE 4 channels 21 5 5 2 DMX functions with DMX MODE 5 channels 21 5 5 3 DMX functions with DMX MODE 6 channels 21 5 6 DMX functions Dynamic white 22 5 6 1 DMX functions...

Страница 3: ...to a qualified technician for any regular maintenance action not described in this manual 1 1 2 Installation The unit installation actions must be performed by a qualified staff 1 1 3 Protection agai...

Страница 4: ...amage the unit 2 0 Size 280m m 11 02in 15mm 0 59in 3 0 m m 1 1 8 i n 263mm 10 35in 232mm 9 14in 150mm 5 91in 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of g...

Страница 5: ...4 1 Build in specifications 4 0 Installation 30mm 1 18in 263mm 10 35in 230mm 9 06in 150mm 5 91in DRAINAGE MATERIAL 18 Italiano...

Страница 6: ...tures are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in...

Страница 7: ...of the accessory Chapter 3 4 1 RDM Dev 5 0 Use of the unit AV TELETEXT 1 AV 79 1 0 PROG PROG P P Warning Before performing any setting operation it is necessary to log in as reported in the chart bel...

Страница 8: ...nal control 0 100 of the White color 5 Dimmer Strobe 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous output intensity 100 0 151 160 Luminous output intensity 0 161 255 P...

Страница 9: ...s output intensity 0 161 255 Proportional control of the strobe effect 0 100 255 max Channel Function Value Description 1 Warm white 0 255 Proportional control 0 100 of the warm white 2 Cold white 0 2...

Страница 10: ...nction MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor R 120 not included Funzione Tasti Descrizione Master Con figuration AV the input or the removing of the automatic mode can...

Страница 11: ...otecting their integrity if the ambient temperature exceeds the one allowed 7 0 Fixed colours mode Function Keys Description Fixed colours mode input The preset colours mode is activated or deactivate...

Страница 12: ...et access to the identification happens by swit ching on at full intensity all the LEDs Manufacturer The name of the manufacturer Griven is displayed Model description The projector model is displayed...

Страница 13: ...mer should contact their local authority or retailer for information concerning the correct disposal of their old appliance 12 0 Spare parts 13 0 Troubleshooting Inconvenience Possibile Cause Action T...

Страница 14: ...nt 0 26A 100V 0 21A 277V Maximum power 57W Thermal protection Electronic Light output source Type of light output source 6 Leds Optics Optical system Lenses Control Protocol USITT DMX 512 Control chan...

Страница 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...

Отзывы: