7.2 Fixed colour mode Dynamic white

7.3 Fixed colour mode monochrome by remote control

7.4 SLAVE configuration RGBW by remote control

To set up the unit as SLAVE set the 5 channels DMX mode with address 001.

7.5 SLAVE configuration Dynamic white by remote control

To set up the unit as SLAVE set the 3 channels DMX mode with address 001.

7.6 SLAVE configuration monochromatic by remote control

To set up the unit as SLAVE set the unit with dmx address 001.

An internal temperature sensor prevents the unit from overheating. The temperature sensor will limit the current

to leds, protecting their integrity, if the ambient temperature exceeds the one allowed.

The POLAR Edition of the projector is fitted with a thermal glass which is particularly useful for outdoor applications.

In fact, by warming up the glass melts ice and snow which might interfere with the projection.

When the projector is on, if required by the weather conditions, the glass is automatically warmed up.  

If the projection is to be started at a definite time, take care to defrost the glass in advance so that the leds can

be lit at the time required.

With very cold temperatures (below -20° C), we recommend you to let the projector always powered and switch

on the LEDs when needed.

Function

Keys

Description

Fixed 

colours

mode input 

The preset colours mode is activated or deactivated by the (TV) key.

Colour se-

lection 

4 / 5

Select the colour whose intensity is intended to be adjusted by the keys 4 or 5

(4=cold white; 5=warm white).

Colour

intensity 

+

-

The intensity of the selected colour, with a 10% increase or decrease, is adjusted

by the VOL+ and VOL- keys.

Function

Keys

Description

Fixed 

colours

mode input 

The preset colours mode is activated or deactivated by the (TV) key.

Colour

intensity 

+

-

The intensity of the white colour is adjusted by the VOL+ and VOL- keys by 

256 steps.

8.0 Thermal protection

9.0 No frost glass

English

27

Содержание RB280

Страница 1: ...Ruby Recessed Manuale di istruzioni Instructions manual...

Страница 2: ...DMX MODE 5 channels 23 5 5 3 DMX functions with DMX MODE 6 channels 24 5 6 DMX functions Dynamic white 24 5 6 1 DMX functions with DMX MODE 2 channels 24 5 6 2 DMX functions with DMX MODE 3 channels...

Страница 3: ...ied technician for any regular maintenance action not described in this manual 1 1 2 Installation The unit installation actions must be performed by a qualified staff 1 1 3 Protection against burns an...

Страница 4: ...t 2 0 Size 280m m 11 02in 15mm 0 59in 3 0 m m 1 1 8 i n 263mm 10 35in 232mm 9 14in 150mm 5 91in 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the f...

Страница 5: ...ons 4 0 Installation 30mm 1 18in 263mm 10 35in 230mm 9 06in 150mm 5 91in DRAINAGE MATERIAL Light direction 5 91in 150mm 1 18in 10 35in 263mm 30mm 1 18in 150mm 9 06in 230mm DRAINAGE MATERIAL tion ec di...

Страница 6: ...on kit to perform the connections Warning Before connecting the unit verify that power supplies features are compatible with the unit features The unit must never be installed if not grounded electric...

Страница 7: ...PROG PROG P P Warning Before performing any setting operation it is necessary to log in as reported in the chart below Function Buttons Description LOGIN 1 2 3 It is the first procedure to be perform...

Страница 8: ...ion Value Description 1 Red 0 255 Proportional control 0 100 of the Red color 2 Green 0 255 Proportional control 0 100 of the Green color 3 Blue 0 255 Proportional control 0 100 of the Blue color 4 Wh...

Страница 9: ...sence of DMX signal the led will remain ON Channel Function Value Description 1 Dynamic white 0 3 Warm white 100 Cold white 0 4 122 Warm white 100 Cold white from 0 to 100 123 132 Warm white 100 Cold...

Страница 10: ...icture shows an example of a Master Slave layout Attention In absence of DMX signal the led will remain ON Channel Function Value Description 1 Dimmer Strobe 0 15 Luminous output intensity 100 16 150...

Страница 11: ...nta red yellow white The pre set time of each scene is 5 seconds If the projector is turned off when it is set in automatic mode it will switch on again in automatic mode with the same se lected scene...

Страница 12: ...nterfere with the projection When the projector is on if required by the weather conditions the glass is automatically warmed up If the projection is to be started at a definite time take care to defr...

Страница 13: ...these instructions 11 1 Cleaning the unit The unit must be cleaned regularly Cleaning regularity will depend especially on the environment where the unit will operate deposits of dust smokes or other...

Страница 14: ...ibile Cause Action The unit does not respond properly to the DMX control Incorrect DMX cable connection Check connections and wires Rectify inefficient connec tions Repair or replace damaged wires Unf...

Страница 15: ...ent 0 37A 100V 0 14 277V Maximum power 37W Thermal protection Electronic Light output source Type of light output source 20 Leds Optics Optical system Lenses Control Protocol USITT DMX 512 Control cha...

Страница 16: ...English 31...

Страница 17: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1...

Отзывы: