background image

AL4362-AL4663-AL4364  MicroParade - Rev. 1.00

page 5 of 8

551047

Configurations

MicroParade 12

 MicroParade 24 

MicroParade 12

MicroParade 12

MicroParade 12

 MicroParade 24 

 MicroParade 24 

 MicroParade 24 

MicroParade 36

MicroParade 36

MicroParade 36

MicroParade 36

MicroParade 12

MicroParade 36

 MicroParade 24 

 MicroParade 24 

Microparade ?

Unit 1

Unit 2

Unit 3

Unit 

44

Unit 

28

Unit 

21

Unit x

Unit 1

Unit 2

Unit 3

Unit 1

Unit 2

Unit 3

Unit 1

Unit 2

Unit 3

Unit 3

0,11A x 45 = 4,95A (< 5A)

0,17A x 29 = 4,93A (< 5A)

0,23A x 21 = 4,83A (< 5A)

Total load ≤ 5A

Start line box 

AL4400

Repower box 

AL4401

AL0512 DMX cable or equivalent

DMX

CONTROLLER

POWER IN

100-240 VAC 

50/60Hz

POWER IN

100-240 VAC 

50/60Hz

Use a DMX repeater on each 32nd fixture of the daisy chain 

or in case the total DMX cable length exceeds 1000 ft (300m).

Install a data terminator on the DMX OUT cable of the last unit 

of the daisy chain as described in the DMX connection kit manual.

For further details on fixture connection and installation, 

please refer to the relevant instruction manual.

120Ω DMX

TERMINATOR

The total load of each series of Microparade must not exceed 5 A.

Il carico totale di ogni singola serie di Microparade non deve superare 5 A.

Example/Esempio:

WARNING ! Use a DMX repeater on each 32nd fixture of the chain or in case the cable lenght exceeds 300m ( 

1000 ft.). Install a data terminator ( 120Ω) between Data+ and Data- on the DMX out cable of the last unit.

ATTENZIONE ! Utilizzare un ripetitore di segnale DMX ogni 32° proiettore della catena o nel caso la lunghezza del 

cavo superi 300 m ( 1000 ft.). Installare un terminatore di linea ( 120 Ω ) tra i poli Data+ e Data- sul cavo dell’ulti

-

mo proiettore.

For further details consult the configuration schemes available on our website.

Содержание MicroParade

Страница 1: ...to 50 C 4 F to122 F Power supply Alimentazione 100 240 VAC 50 60Hz Inrush current Corrente di spunto 40A 230 VAC cold start Power Potenza massima 11 W 19 W 28 W Nominal current Corrente nominale 0 11A...

Страница 2: ...ve cables and connectors unconnected or unprotected for long periods Non lasciare mai per lungo tempo agli agenti atmosferici cavi e connettori non collegati o non protetti Disconnect power before ins...

Страница 3: ...5 8 40mm 24 1 8 614mm 7 7 8 200mm 1 26mm 2 7 8 72mm 1 26mm 7 7 8 201mm 2 1 2 63mm 36 5 8 929mm 3 1 2 88mm 1 5 8 40mm 36 914mm 19 5 8 500mm 2 50mm 3 8 8mm 19 5 8 500mm 2 50mm 3 8 8mm 36 5 8 929mm 3 1...

Страница 4: ...specializzato WARNING Ensure power supply is off before connecting or disconnecting fixtures ATTENZIONE Assicurarsi che l alimentazione sia disattivata prima di collegare o scollegare i proiettori Be...

Страница 5: ...ble length exceeds 1000 ft 300m Install a data terminator on the DMX OUT cable of the last unit of the daisy chain as described in the DMX connection kit manual For further details on fixture connecti...

Страница 6: ...ntroller will display the xture on a list DMX address reading and setting Channels number reading and setting On Off identi cation This command is used to identify the xture you want to get access to...

Страница 7: ...page 7 of 8 551047 Order codes AL4362 AL4363 AL4364 optics LED type option OPTICS LED TYPE OPTION EL Elliptical RW RGBW 01 in out power DMX cables WW Wall Wash DW Dynamic White 02 in out power DMX cab...

Страница 8: ...AL4362 AL4663 AL4364 MicroParade Rev 1 00 page 8 of 8 551047...