Electrical connection
1) Cable the 32 Amps Gewiss plug to a mains cable 3x2,5mm.
2) Connect the lantern to a mains supply of 230V - 50/60Hz.
3) Ensure that the mains cable is connected to earth; the thermoswitch must have the following
electrical characteristics:
lamp 1200 HMI = rated for (In) 20A - sensitivity (Id) 0,3A
lamp 2500 HMI = rated for (In) 25A - sensitivity (Id) 0,3A
USE OF THE LANTERN
Function in automatic mode
Once the lantern is connected to the mains and the general mains switch is activated the lantern can
run in manual mode.
It will be possible to adjust:
- strobe and black-out
- beams rotation speed
- scanning speed
- scanning amplitude
To access the control panel, unscrew the 2 knobs located on the side of the lower part of the lantern
and open the protecting cover.
Function in 0/10V mode
To manually control the SKY ROSE by remote control, connect the 4 jack mono plugs supplied to
a 0/10V controller (as per dwg).
CONTROL PANEL