background image

24

English

7.2 AUTOMATIC configuration RGBW

To activate the AUTOMATIC mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN”

keys select “AUT”. Press “ENTER” to confirm.

Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to

activate or deactivate the AUTOMATIC mode. Press “ENTER” to confirm.

It is possible to adjust the length of time of the scenes of the programmes.

Through the “UP” and “DOWN” keys select “TI” and press “ENTER” to confirm. Through the “UP” and “DOWN” keys

select the length of time desired (5-10-20-40 seconds) and press “ENTER” to confirm.

Now, through the “UP” and “DOWN” keys, it is possible to scroll the 8 preset programmes (P1-P8). Once positioned

onto the desired programme, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or “OFF”. It is

possible to activate or disactivate the programme. Press ENTER to confirm. 

Now the unit is in AUTOMATIC mode and the diplay will keep reading “AUT”.

To exit from the AUTOMATIC mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm. 

Select “OFF” to deactivate the AUTOMATIC mode. Press ENTER to confirm. 

The following table shows the light output colour effect according to the programme (RGBW).

7.3 MASTER configuration

To set up the unit as MASTER the same instructions for the set up as AUTOMATIC must be followed.

7.4 SLAVE configuration RGBW

To set up the unit as SLAVE set the DMX mode with address 001.

7.5 SLAVE configuration DW

To set up the unit as SLAVE set the 3 channels DMX mode with address 001.

In the FIXED COLOURS mode, it is possible to manually turn on the LEDs, without the use of a DMX.

In this mode, the projector also behaves as a master and can control a number of projectors SLAVE.

8.1 RGBW MASTER configuration

To activate the FIXED COLOUR mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and

“DOWN” keys select “COL”. Press “ENTER” to confirm.

Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to

activate or deactivate the FIXED COLOUR mode. Press “ENTER” to confirm.

Now, through the “UP” and “DOWN” keys, it is possible scroll the colours.

Warning! 

It is possible to select more programmes which will be executed in sequence.

If MASTER-SLAVE mode is being used, the fixture cannot be controlled by a DMX control device 

and no other DMX control device must be present along the line!! 

If the DMX connectors in the rear panel of the unit are not used, 

they are to be connected one with each other, in order to preserve the IP65 protection rate.

Program N° Effect

1

Red - Magenta - Yellow

2

Red - Magenta - Yellow - White

3

Green - Cyan - Yellow

4

Green - Cyan - Yellow - White

5

Blue - Cyan - Magenta

6

Blue - Cyan - Magenta - White

7

Green - Cyan - Blue - Magenta - Red - Yellow

8

Green - Cyan - Blue - Magenta - Red - Yellow - White

8.0 FIXED COLOURS mode

Содержание EM437

Страница 1: ...EMERALD Manuale di istruzioni Instructions manual...

Страница 2: ...1 DMX functions with DMX MODE 4 channels 21 6 3 2 DMX functions with DMX MODE 5 channels 21 6 3 3 DMX functions with DMX MODE 6 channels 22 6 4 DMX functions DW 22 6 4 1 DMX functions with DMX MODE 2...

Страница 3: ...described in this manual 1 1 2 Installation Fix the unit with screws hooks or any other support able to bear the weight of the unit itself The unit installation actions must be performed by a qualifie...

Страница 4: ...0 Size 249mm 9 80 437mm 17 20 341mm 13 43 260mm 10 24 6 50mm 0 26 12 50mm 0 49 58mm 2 28 129 74mm 5 11 173 50mm 6 83 3 0 Packaging and transport Warning Griven S r l liability will cease upon consign...

Страница 5: ...position Use the holes 12 5 1 2 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 4 2 Rotate the bodies of the unit towards desired direction...

Страница 6: ...s are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in for...

Страница 7: ...anel The display of the unit is programmed to turn off automatically after 20 seconds of non working To activate it just press UP DOWN UP DOWN keys When the display is actice the luminous intensity is...

Страница 8: ...rm 6 3 DMX functions RGBW 6 3 1 DMX functions with DMX MODE 4 channels 6 3 2 DMX functions with DMX MODE 5 channels 6 0 DMX function mode Warning In absence of DMX signal the led will remain OFF Chann...

Страница 9: ...In absence of DMX signal the led will remain ON Channel Function Value Description 1 Dynamic white 0 3 Warm white 100 Cold white 0 4 122 Warm white 100 Cold white from 0 to 100 123 132 Warm white 100...

Страница 10: ...AUT Press ENTER to confirm Through the UP and DOWN keys select ACT Through the UP and DOWN keys select ON or OFF to activate or deactivate the AUTOMATIC mode Press ENTER to confirm The projector will...

Страница 11: ...up as AUTOMATIC must be followed 7 4 SLAVE configuration RGBW To set up the unit as SLAVE set the DMX mode with address 001 7 5 SLAVE configuration DW To set up the unit as SLAVE set the 3 channels D...

Страница 12: ...ay will keep reading COL To exit from the FIXED COLOURS mode press the MENU button select ACT and press ENTER to confirm Select OFF to deactivate the FIXED COLOURS mode Press ENTER to confirm 8 3 SLAV...

Страница 13: ...e those components which have got deteriorated All components of the unit are available as spare parts at Griven dealers Exploded views wiring diagrams electronic layouts and advertising brochures are...

Страница 14: ...fficient connec tions Repair or replace damaged wires Unfinished data connection Insert a terminal plug in the output jack of the last unit of the connection Incorrect address assignment to the units...