Capital - Rev. 1.0
page 4 of 12
Connection
RED= DMX +
BLACK= DMX -
WHITE=COMMON
RED= DMX +
BLACK= DMX -
WHITE=COMMON
Blue= N (Neutral)
Brown=L (Live)
Yellow/Green=GND
MAINS:
100-277VAC 50/60Hz
“S” type cable ( Power in, DMX In, DMX Out )
RED= DALI bus +
BLACK= DALI bus -
RED= DALI bus +
BLACK= DALI bus -
Blue= N (Neutral)
Brown=L (Live)
Yellow/Green=GND
“D” type cable ( Power in, DALI In, DALI Out )
DMX IN/OUT
DALI IN/OUT
RED= DMX +
BLACK= DMX -
WHITE=COMMON
RED= DMX +
BLACK= DMX -
WHITE=COMMON
Blue= N (Neutral)
Brown=L (Live)
Yellow/Green=GND
MAINS:
100-277VAC 50/60Hz
DMX IN/OUT
RED= DALI bus +
BLACK= DALI bus -
RED= DALI bus +
BLACK= DALI bus -
Blue= N (Neutral)
Brown=L (Live)
Yellow/Green=GND
DALI IN/OUT
MAINS:
100-277VAC 50/60Hz
MAINS:
100-277VAC 50/60Hz
Note: the power and signal connections of S and M cable types can be carried out by using the
connection kit included in the packing box. Follow the instructions provided along with the con-
nection kit.