background image

Dune MC MK3 

User Manual

Griven S.r.l.

 - Via Bulgaria, 16

46042 Castel Goffredo

Mantova -  Italy

© Copyright Griven 2017 - Griven reserves the right to make 

changes to this product and related instructions at any time 

without prior notice and such changes shall be effective 

immediatly

.

Tel. +39.0376.779483

E-mail: [email protected]

Web: 

www.griven.com

AL5004

Rev. 2.00

Date: 19/10/2022

Typical system diagram:

OUT

IN

OUT

IN

OUT

IN

Line terminator 

120Ω  

(not included)

SLAVE 1

eg: CH001

SLAVE n#

eg: CH001

MASTER

eg: CH001

WARNING ! in this mode, no other DMX control device must be present along the line.

ATTENZIONE ! in questa modalità non devono essere presenti altri controller DMX sulla linea.

MASTER-SLAVE - AUTOMATIC mode

SLAVE 2

eg: CH001

OUT

IN

DMX cable

OUT

IN

DMX cable

OUT

IN

DMX cable

Line terminator 

120Ω  

(not included)

SLAVE 1

eg: CH005

SLAVE n#

eg: CHxxx

MASTER

eg: CH001

DMX mode

SLAVE 2

eg: CH009

DMX

controller

IN

DMX cable

WARNING ! Use a DMX repeater on each 32nd fi xture of the chain or in case the cable lenght exceeds 300m ( 

1000 ft.). Install a data terminator ( 120Ω) between Data+ and Data- on the DMX out cable of the last unit.

ATTENZIONE ! Utilizzare un ripetitore di segnale DMX ogni 32° proiettore della catena o nel caso la lunghezza del 

cavo superi 300 m ( 1000 ft.). Installare un terminatore di linea ( 120 Ω ) tra i poli Data+ e Data- sul cavo dell’ulti-

mo proiettore.

For further details consult the confi guration schemes available on our website.

Содержание AL5004

Страница 1: ...bs Housing Corpo proiettore AISI 316L stainless steel in ABS formwork IK rating classe IK IK10 IP rating grado IP IP68 1 5M Ambient temp Temperatura ambientale 40 C to 50 C 40 F to122 F Power supply A...

Страница 2: ...ell apparecchiatura Disconnect power before any connection operation Togliere l alimentazione prima di effettuare qualsiasi operazione di connessione tra gli apparecchi Check voltage and frequency bef...

Страница 3: ...551119 AL5004 Dune MC MK3 page 3 of 9 Installation 1 2 3 4 5 6 8 9 40 10 7 2 4 6 8 40 10 1 2 3 4 5 6 8 40 7 2 4 6 8 40 1 2 3 4 5 6 8 40 7 2 4 6 8 40 M5 M6 Installazione...

Страница 4: ...MATERIAL MATERIALE DI DRENAGGIO 0 mm Aim this sticker towards the wall that should be illuminated Orientare questa segno verso il muro da illuminare Installazione Never install the formwork below grou...

Страница 5: ...0 Km Mains Power 100 240 VAC 50 60Hz Mains Power 100 240 VAC 50 60Hz DMX cable type 2x0 34 mmq shielded impedance 110 capacity 43pF m resistance 50 Km Beam aimig Beam angle can be varied from 9 to 9 R...

Страница 6: ...t non devono essere presenti altri controller DMX sulla linea MASTER SLAVE AUTOMATIC mode SLAVE 2 eg CH001 OUT IN DMX cable OUT IN DMX cable OUT IN DMX cable Line terminator 120 not included SLAVE 1 e...

Страница 7: ...BLUE BLU 4 WHITE BIANCO DIMMER MODE Monochromatic 0 100 100 0 5 inactivity Automatic LOGOUT 5 inattivit Automatic LOGOUT Green Cyan Blue Magenta Red Yellow White Verde Ciano Blu Magenta Rosso Giallo B...

Страница 8: ...ostrato il modello del proiettore Software version description viene mostrata la attuale versione software installata sull apparecchio Temperature viene mostrata l attuale temperature dei LED Mode Mod...

Страница 9: ...ntando il proiettore se la temperatura lo richiede si scalda il vetro termico che rimane attivo no al raggiungimento della temperatura di esercizio POWER ON LEDs OFF LEDs ON If the projection is to be...

Отзывы: